Table of Contents

Advertisement

O
M
perating
anual
D-ACTOR
200
®
BS.####
Part No. 19700.01xx
Published: January 2017
Original language: German
Publisher:
STORZ MEDICAL AG
Lohstampfestr. 8
CH-8274 Tägerwilen
Switzerland
27789

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D-ACTOR 200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Storz D-ACTOR 200

  • Page 1 D-ACTOR ® BS.#### Part No. 19700.01xx Published: January 2017 Original language: German Publisher: STORZ MEDICAL AG Lohstampfestr. 8 CH-8274 Tägerwilen Switzerland 27789...
  • Page 2: Table Of Contents

    Table of Contents General Safety Information Instructions for safe use 1.1.1 Designated use and operational safety. 1.1.2 Safety during treatment of the patient. Warning against damage to equipment and the device Principles Physical principles 2.1.1 Indications . 2.1.2 Contraindications . 2.1.3 Side effects .
  • Page 3 Operation of the handpiece Operation of the Touch Screen of the Tablet PC 4.4.1 Module selection . . 23 4.4.2 Parameter selection and counter display . . 24 4.4.3 Contact intensity and Skin Touch display . . 26 4.4.4 Treatment menu bar . .
  • Page 4 4.10 Treatment with D-ACTOR or V-ACTOR handpiece 4.10.1 Setting parameters . 56 4.10.2 Coupling the handpiece . . 56 4.10.3 Triggering pulses . . 56 4.10.4 Functions overview of the handpiece D-ACTOR . . 56 4.11 Treatment with VACU-ACTOR 4.11.1 Using the foot switch .
  • Page 5 Preface Warning notes This manual contains warnings, safety instructions and specific operating instructions in accordance with liability regulations. DANGER refers to a situation of acute danger which, if not avoided, could lead to serious or fatal injury. DANGER! The source of the danger is stated here. These are the possible consequences! •...
  • Page 6: General Safety Information

    The device is only allowed to be used for the applications described in C 2.1.1 hapter ndiCatiOns • Only perform treatments approved by STORZ MEDICAL AG! Furthermore, the device is only allowed to be operated by trained personnel who comply with the p in C 2.2.
  • Page 7: Safety During Treatment Of The Patient

    • Disconnect the connected handpieces from the device before carrying out cleaning and maintenance work. Do not reconnect them until they have been completely reassembled! • The optional KARL STORZ foot switch must not be used in potentially explosive atmospheres according to classification AP as per IEC 60601. Protection against noise The noise level during administration of pulses is within the safe area.
  • Page 8 The use of accessories or cables that are not authorised by the manufacturer can result in increased interference emissions or reduced resistance to interference emissions by the device. The D-ACTOR 200 is not allowed to be positioned immediately next to or jointly ®...
  • Page 9: Principles

    (athmospheric pressure). This function is realized by a high-performance compressor. 2.1.1 Indications The D-ACTOR 200 is designed for pulse activation treatment (PAT) intended to relieve minor muscle aches and pains. 2.1.2 Contraindications...
  • Page 10: Side Effects

    An introduction to the principles of operation will be provided by your STORZ MEDICAL dealer with reference to this operating manual and will be documented in the system logbook. The operator must be instructed in the following points: –...
  • Page 11 Further information about training in the operation of this system can be obtained from your STORZ MEDICAL dealer. However, you can also contact the following address directly:...
  • Page 12: System Description

    System Description Control and functional elements The D-ACTOR ® 200 is exclusively controlled using the operating and display elements on the handpiece. 1 Handpiece connector V-ACTOR 2 Handpiece connector D-ACTOR 3 Handpiece connector D-ACTOR 4 Connector VACU-ACTOR Fig. 3-1 Front and right side of D-ACTOR ®...
  • Page 13: Scope Of Supply

    1 Opening for the nebulizer 2 Openings for handpiece holder Fig. 3-3 Bottom side D-ACTOR ® Scope of supply The standard scope of supply of the D-ACTOR ® 200 includes the following items: – D-ACTOR 200 control device ® – Mains cable (EU / USA) –...
  • Page 14: Transport

    There are openings for 6 handpiece holders and /or suction cup holder - 3 on the right side and 3 on the left side of the D-ACTOR 200 in each case in the front, in the middle and rear section.
  • Page 15: Suction Cup Holder

    The mounting of the handpiece holder is equal for both types. • Push the holder into the provided openings at the D-ACTOR 200. ® 3.5.1.2 Suction cup holder 1 Openings for insertion of the handpiece and suction cup holder Fig. 3-6 Mounting the suction cup holder •...
  • Page 16: Connecting The Potential Equalisation

    • Connect the cable for the potential equalisation to the PE connector of the D-ACTOR 200 (Fig. 3-7/2) and connect it to your PE connector. 3.5.4 Connecting handpiece •...
  • Page 17: Connecting Vacu-Actor

    1 USB connector for connecting Tablet PC 2 Footswitch connector Fig. 3-10 Connection of tablet and footswitch - D-ACTOR 200 rear side • Connect the USB connector of the tablet into the USB connector on the rear side of the D-ACTOR 200.
  • Page 18: Connecting The Foot Switch

    Treatment with the VACU-ACTOR can be activated and deactivated with the aid of the foot switch. Fig. 3-13 Optional Karl Storz foot switch Compatibility The STORZ MEDICAL D-ACTOR 200 is allowed to be operated with the following handpieces: – handpiece D-ACTOR part.no. 21700.xxxx –...
  • Page 19: Symbols

    Symbols You must read the operating manual Application unit of type B Potential equalisation Connector D-ACTOR handpiece Connector V-ACTOR handpiece Connector VACU-ACTOR USB-connector CE mark (in accordance with the Medical Device Directive (MDD) 93/42/EEC) CSA test mark WEEE label wearing ear protection 19 620 02 0117...
  • Page 20: Operation

    • Switch on the device using the main switch on the rear side of the device. 1 main switch Fig. 4-1 Main switch Operation The following options for operating the D-ACTOR 200 are available: – D-ACTOR 200 with D-ACTOR handpiece – via the display of the handpiece – via the tablet touch screen –...
  • Page 21: Operation Of The Handpiece

    Operation of the handpiece This device can be controlled directly using the handpiece. Corresponding setting buttons can be used for selecting the treatment parameters. The indicator window shows which setting has been selected. 1 decrease energy 2 increase energy 3 decrease frequency 4 increase frequency 5 Trigger button 6 Display energy...
  • Page 22: Operation Of The Touch Screen Of The Tablet Pc

    When using the D-ACTOR handpiece or V-ACTOR handpiece as well as the VACU- ACTOR the D-ACTOR 200 can also be controlled by a colour TFT monitor with touch screen function. This allows individual adjustment of the parameters for the V-ACTOR handpiece as well as the VACU-ACTOR.
  • Page 23: Module Selection

    4.4.1 Module selection The field at the top left is used for displaying the operating modes that can be se- lected. Once a handpiece or the VACU-ACTOR is connected, it is possible to activate the corresponding operating mode in the mode selection area. The active module button is highlighted. Fig. 4-4 Mode selection field Symbols Meaning Vibration therapy: Select V-ACTOR D-ACTOR mode: Select handpiece 1 D-ACTOR mode: Select handpiece 2 suction cup therapy: Select VACU-ACTOR...
  • Page 24: Parameter Selection And Counter Display

    4.4.2 Parameter selection and counter display The PARAMETER SELECTION field is used for displaying and setting the treatment parameters. Operating mode D-ACTOR Here you define the energy level as well as the number and frequency of the pulses before each treatment. Fig. 4-5 Setting parameters - operating mode D-ACTOR Symbols Meaning Set the energy level: increase / reduce The set energy is displayed Setting nominal pulse value: increase / reduce The set number of pulses is displayed...
  • Page 25 The desired energy level, nominal pulse value and frequency can be achieved more quickly by keeping the Increase/Reduce button pressed down. Operating mode VACU-ACTOR Fig. 4-6 Setting parameters - operating mode VACU-ACTOR Symbols Meaning Set intensity: decrease / reduce It can be selected from 1 to 5. Set time limit: decrease / reduce...
  • Page 26: Contact Intensity And Skin Touch Display

    Tabelle 4 -3 Setting parameters Explanation of terms Mode VI The suction cup creates an interaction of vacuum and positive pressure with the adju- sted frequency. Mode VC The suction cup creates a negative pressure. It pulsates between vacuum and ventila- tion by different frequency settings.
  • Page 27 For this purpose consider the following notes: CAUTION! Danger of injury from inadvertent pulse triggering Trigger pulses only when the handpiece is in contact with the in- tended treatment zone. Avoid accidental contact between the patient and the handpiece when the Skin Touch function is activated. •...
  • Page 28: Treatment Menu Bar

    4.4.4 Treatment menu bar Use the TREATMENT menu bar to call up stored treatment parameters and treatment reports as indications. Fig. 4-8 Treatment menu bar Buttons Meaning Markers for various The ANATOMY view appears automatically when the treatment zones device is started. Press the corresponding markers to call up factory-set or user-defined indications for the various treatment zones.
  • Page 29: Device Info And Settings Menu Bar

    4.4.5 Device info and settings menu bar The bottom navigation bar contains control buttons used for navigating through the menus: – Software update – Options – Service VERSIONS – Serial number and indices of the individual components OPERATING DATA – Total pulse count and device operating hours (depending on operating mode selected) –...
  • Page 30: Touch Screen Operation

    Touch screen operation 4.5.1 Configuration and reset When starting the tablet the first time the touchscreen displays the content shown in Fig. 4-9. While the first connection of the tablet to the device the tablet will be confi- gured automatically for this device. Fig. 4-9 Tablet - start page Reset tablet to the factory default settings • Press • Use the opened menu bar to select the function. Fig. 4-10 Password screen for resetting the device type •...
  • Page 31: Password Protection

    Fig. 4-11 Reset system configuration • Confirm „Reset system configuration?“ by pressing – The tablet will now be reset and all stored patient and treatment data will be deleted. • Now start the tablet anew. 4.5.2 Password protection It is possible to protect your SMAG tablet with a password. If starting the tablet anew or if it is in screen saver mode so the display is locked and can only be unlocked by entering the password.
  • Page 32 Fig. 4-13 Password entry • Confirm with h Your password is activated. Deactivate password protection • Press several seconds on date and time field • Press to deactivate password entry (the check mark needs to be can- celled after that). • Type now your password on the following screen.
  • Page 33: Setting Brightness And Volume

    4.5.3 Setting brightness and volume • Select • Select in the open top menu bar. Fig. 4-15 Options • Tap on the scale at the desired position in order to adjust the brightness of the screen or the volume. • Press to save the settings.
  • Page 34: Selecting Treatment Parameters

    The operating mode is exited if you – select another mode – load an indication which requires working in another mode – operate another handpiece 4.5.5 Selecting treatment parameters You can set the treatment parameters manually or load a predefined indication. For manual selection • Set the energy level as well as the number and frequency of the pulses using the buttons in the PARAMETER SELECTION field.
  • Page 35 To load only the indications for a particular treatment zone • Press the marker for the treatment zone. Fig. 4-18 Selectable treatment zones – The alphabetically sorted list of indications for this treatment zone is opened. Navigating in the list Use the navigation bar on the right edge of the display to move within the list.
  • Page 36 Fig. 4-20 Overview - information about stored indications Calling up detailed views: For increased clarity, you can call up magnified views of the treatment photos as well as the recommended transmitters and stand-off devices. • Press the corresponding treatment photo. – The display shows a magnified view of the picture. Fig. 4-21 Treatment photo detailed view • Press the underlined transmitter or stand-off device name. –...
  • Page 37 Fig. 4-22 D20 detailed view Use the buttons to switch to the display of the previous or next element. • Press to switch to the treatment step overview. Loading treatment steps • Load the first treatment step using the button in front of it. – The treatment parameters are accepted and displayed in the PARAMETER SELECTION field of the display.
  • Page 38: Saving Indications

    Loading a patient dataset You can now call up a patient record directly from the loaded indication. • Press – The list of stored patient data is opened. • Load the required dataset by pressing – The name of the patient is displayed in the status bar with the loaded indication.
  • Page 39: Copying Indications

    • Use the onscreen keypad to enter an indication name and treatment region. • Save your entry by pressing • Create a treatment step (see C 4.5.10.3). hapter • Save your entry by pressing NOTE An empty indication without any entryof a treatment step will not be saved. h Your indication is now created in the system.
  • Page 40: Deleting An Indication

    4.5.9 Deleting an indication • Press – The list of indications is displayed. • Select the indication that you want to delete by pressing the button in front of – The indication is opened. DELETE INDICATION. • Press • Confirm your input by pressing NOTE This only applies to your own indications.
  • Page 41: Storing Treatment Notes

    4.5.10.1 Storing treatment notes • To add remarks to the indication, press in the line. Using the onscreen keypad, you can now enter your remarks and notes in the text box. • Save your text by pressing h The text appears in the overview window of the indication. 4.5.10.2 Loading images and/or videos Not only images but also videos can be loaded in WMV format.
  • Page 42: Creating, Deleting Or Editing Treatment Steps

    Deleting pictures and/or videos • To remove a picture or a video from the picture line, press on the symbol in the picture and confirm your entry with h The picture or video is deleted from the indication. 4.5.10.3 Creating, deleting or editing treatment steps • Press to create a treatment step.
  • Page 43: Loading Patient Data

    4.5.11 Patient treatment report Each treatment of a patient can be recorded in a treatment report and stored. 4.5.11.1 Loading patient data • Press in the top menu bar. – The alphabetically sorted list of patient data is opened. Fig. 4-31 List of stored patient data Navigating in the list Use the navigation bar on the right edge of the display to move within the list.
  • Page 44 Fig. 4-32 Patient data • In the TREATMENTS line, press the button to call up details. – You can now see which parameters have been used for the patient’s treat- ment. Fig. 4-33 Treatment parameters used 19 620 02 0117...
  • Page 45: Editing Patient Data

    4.5.11.2 Editing patient data You can add additional notes or treatment pictures by setting the dataset to editing mode. • Press the button to do this. The buttons with the pencil icon indicate the areas that can be edited. You can now: –...
  • Page 46: Creating New Patient Data

    4.5.12 Creating new patient data • Press in the top menu bar. – The alphabetically sorted list of patients is opened. • Press – A window with a keypad and text boxes for the patient data is opened. Fig. 4-35 Creating a new patient •...
  • Page 47: Exporting Treatment Data

    4.5.13 Exporting treatment data This function can be used to export treatment data to a USB memory stick as Excel-readable files. • Ensure that your USB stick supports the USB V1.1 protocol. You can order a validated USB stick from your dealer. •...
  • Page 48: Software Updates

    – On the display of the handpiece the values of the energy are blinking if the update is finished. • Confirm the energy values. h Now you can go on with treatment. NOTE The Software Update for the D-ACTOR 200 need to be performed separately. An Update over the Tablet PC is not possible. 19 620 02 0117...
  • Page 49: Changing Software Settings

    4.5.17 Changing software settings This function enables you to activate or deactivate indication groups. • Press • In the open menu list, select the function. Fig. 4-37 Options: Orthopaedics active You see the list of possible indication groups. symbol before an indication group indicates that it is activated. •...
  • Page 50: Starting Visible Body

    4.5.18.1 Starting Visible Body • To start Anatomy Atlas, press Fig. 4-38 Visible Body - Main menu Fig. 4-39 Visible Body - Selection of the muscle region 19 620 02 0117...
  • Page 51: Marking Treatment Regions

    4.5.18.2 Marking treatment regions • To load the marking pencil, press Fig. 4-40 Visible Body - Marking the treatment region • Now draw your markings of the region on the control panel. Fig. 4-41 Visible Body - Marked region • Press the symbol to create a screenshot.
  • Page 52: Exiting Visible Body

    4.5.18.3 Exiting Visible Body • To exit the program, press on a module selection field (D-ACTOR) or the empty area located below on the left that is outside the Visible Body screen. Fig. 4-42 Exit Visible Body Setting treatment parameters • Set the treatment parameters by pressing buttons on the handpiece display or on the tablet. –...
  • Page 53: Start-Up

    Start-up • Set the energy of the pulses to an initial value of 2 bar The maximum pressure is limited to 5.0 bar . The minimum pressure that can be set is 0.3 bar The D-ACTOR handpiece can be operated in single pulse mode and in continuous pulse mode.
  • Page 54: Treatment With D-Actor Or V-Actor Handpiece

    Standard settings • Before each treatment, make sure that the pulse counter is set to zero. NOTE Set the nominal value counter to the required value. D-ACTOR • Start the D-ACTOR treatment at a pressure of 2 bar and a frequency of 5 Hz. V-ACTOR •...
  • Page 55 CAUTION! Malfunction of the device or its components Various injuries are possible! • Immediately comply with all status and error messages which appear during the treatment (see Operating Manual of the handpiece). CAUTION! Over extended periods, the noise of the pulses can be per- ceived as unpleasant! •...
  • Page 56: Setting Parameters

    4.10.1 Setting parameters Treatment should always start at a low energy level. This also applies to resuming treatment after an interruption. The pulse energy should be increased gradually during treatment. The low levels are used less for therapy and more for familiarising the patient.
  • Page 57: Treatment With Vacu-Actor

    4.11 Treatment with VACU-ACTOR CAUTION ! Do not apply the VACU-ACTOR in the face. Do not apply the VACU-ACTOR longer than 30 minutes. Do not use damaged suction cups. Only perform treatment in a dry state. Blood cupping is not allowed! Only perform treatment at healthy and intact skin! Avoid hematoma, pain and tissue damage! •...
  • Page 58: Using The Tablet Pc (Optional)

    4.11.2 Using the Tablet PC (optional) When using the Tablet the preadjusted parameters can be varied. See for this C hapter 4.4 O peratiOn Of the OuCh Creen Of the ablet • Adjust the intensity, the frequency and the time limit on the touch screen. •...
  • Page 59: Cleaning, Maintenance, Overhaul

    Cleaning, Maintenance, Overhaul Cleaning Regular cleaning of the system ensures perfect hygiene and operation of the D-ACTOR ® 200. CAUTION! Electrical hazard! Disconnect the device and the accessories from the mains before starting any cleaning and overhauling work! Overall external cleaning depends on the frequency of use and application of the device.
  • Page 60: Reconditioning The Vacu-Actor

    5.1.3 Reconditioning the VACU-ACTOR ATTENTION ! After each application of the device with the suction cup all reusable parts which have been in contact with the patient need to be cleaned and disinfected. After each application of the device with the suction cup all reusable parts which have been in contact with the patient need to be reconditioned for further application, to get the parts free of microorganism.
  • Page 61: Cleaning

    5.1.3.2 Cleaning The suction cup made of polycarbonate has a pore-free surface so that dirt does not cling easily to it. • Wipe the suction cup with a soft tissue moistened with water (recommended is microfibre), never rub with a dry tissue! NOTE Never rub the suction cup with a dry tissue. For efficient cleaning we recommend using a non abrasive detergent suitable for polycarbonate.
  • Page 62: Fuse Replacement

    Maintenance services can be ordered from our regional representatives in your area or directly from STORZ MEDICAL AG. Independently of the national accident prevention regulations and test and inspection intervals prescribed for medical devices, we recommend that functional checks (see 4.8 f...
  • Page 63: Disposal

    Repair work on defective devices must only be carried out by personnel suitably authorised by STORZ MEDICAL. Only original STORZ MEDICAL spare parts may be used for this purpose. The personnel suitably authorised can be from STORZ MEDICAL or be representatives of STORZ MEDICAL agencies and dealers.
  • Page 64: Accessories

    Accessories Mains cable CEE 4 m long 13455 Mains cable CH 3 m long 13448 D-ACTOR »Falcon« handpiece set 21700.1001 D-ACTOR »Falcon« overhaul kit 26894 C15 transmitter 19222 F15 transmitter 21356 DI15 transmitter 21374 D20-S transmitter 21004 D20-T transmitter 21125 D35-S transmitter 21122 V-ACTOR handpiece...
  • Page 65: Technical Specifications

    Technical Specifications Technical Specifications D-ACTOR ® single pulse mode, continuous pulse mode D-ACTOR operating mode HP 21700.0001: 1-21 Hz / 1-5 bar in steps of 0.1 bar HP 21700.1001: 1-21 Hz / 0.3-5 bar operating mode V-ACTOR: - standard 31 Hz / 2,4 bar - when using an 1 - 35 Hz / 1 - 5 bar external display...
  • Page 66: Type Plate D-Actor ® 200

    For the technical specifications of the handpieces, please refer to the operating manual for your particular handpiece. Equipment safety (“essential performance“) according to IEC 60601-1, 3rd edition: Applied acoustic energy does not exceed the specified limit of 6.5 bar with a tolerance of 10%. The applied underpressure with the suction cup is limited to -500 mbar. NOTE When the medical product is distributed to third parties, the following must be observed: –...
  • Page 67: Conformity With Standards

    Conformity with standards No. 601.1, This device complies with the applicable standards EN 60601-1, CAN / CSA-C22.2 UL Std. No. 60601-1. Acc. to EN 60601-1 - Type of protection against electric pulses: Protection class 1 - Application unit of type B 7.4.1 EMC guidelines and manufacturer’s declaration Guidelines and manufacturer's declaration –...
  • Page 68 Guidelines and manufacturer's declaration – Resistance to emitted electromagnetic interference ® The D-ACTOR 200 model is intended for operation in the electromagnetic environment specified below. ® The customer or the user of the D-ACTOR 200 should ensure that it is used in such an environment. IEC 60601 Compliance Electromagnetic environment – Immunity tests test level level...
  • Page 69 Guidelines and manufacturer's declaration – Resistance to emitted electromagnetic interference ® The D-ACTOR 200 model is intended for operation in the electromagnetic environment specified below. ® The customer or the user of the D-ACTOR 200 should ensure that it is used in such an environment. IEC 60601 Compliance Immunity tests Electromagnetic environment – guidelines test level level Portable and mobile RF equipment should be used no...
  • Page 70 Recommended safety distances between portable and mobile HF communications equipment and the D-ACTOR ® ® The D-ACTOR 200 is intended for use in an electromagnetic environment in which radiated HF ® disturbances are controlled. The customer or the user of the D-ACTOR 200 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile HF ®...
  • Page 71: Certificates

    Certificates Fig. 7-2 Declaration of conformity 19 620 02 0117...
  • Page 72: Symbols And Labels

    Symbols and labels The following symbols and labels are attached to the D-ACTOR ® 200: Label Name Type plate 220 - 230 VAC Type plate 115 VAC You must read the operating manual WEEE symbol Tabelle 7 -7 Labelling 19 620 02 0117...
  • Page 73: Warranty And Service

    Transport costs and the risk of loss during the shipping of returned products shall be borne by the customer. Please complete the attached warranty card and return it as soon as possible to the address below: STORZ MEDICAL AG Lohstampfestrasse 8 CH-8274 Tägerwilen Warranty for the handpiece The warranty conditions for the handpiece can be found in the operating manual for the corresponding handpiece.
  • Page 74 19 620 02 0117...

Table of Contents