Download Print this page

Panduit CJRR Series Installation Instructions

Rca and s-video punchdown modules

Advertisement

Quick Links

© Panduit Corp. 2007
TERMINATION INSTRUCTIONS
STEP 1
Remove approximately 1" of cable jacket. (CAUTION: Do not damage conductors.) Fan out twisted pairs
for termination.
STEP 2
Use the PDT110 Single Wire Punchdown tool to punchdown conductors in the orientation shown.
RCA Module
S-Video Module
Modules should appear as shown below when terminated.
RCA Module
** Denotes color.
For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
Signal Ground
Signal
Signal and Signal Ground use one twisted pair
Chrominance
Chrominance Ground
Luminance Ground
Luminance
Chrominance and Chrominance Ground use one twisted pair
Luminance and Luminance Ground use one twisted pair
M
-C
RCA and S-Video
INI
OM
110 Style Punchdown Modules
Part Numbers: CJRY**, CJRR**, CJRW**, CJSV**
PN194D
S-Video Module
Page 1 of 2

Advertisement

loading

Summary of Contents for Panduit CJRR Series

  • Page 1 RCA and S-Video 110 Style Punchdown Modules Part Numbers: CJRY**, CJRR**, CJRW**, CJSV** INSTALLATION INSTRUCTIONS PN194D © Panduit Corp. 2007 TERMINATION INSTRUCTIONS STEP 1 Remove approximately 1" of cable jacket. (CAUTION: Do not damage conductors.) Fan out twisted pairs for termination.
  • Page 2 3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface. 4. Use caution when installing or modifying communication wiring. E-mail: For Instructions in Local Languages cs@panduit.com and Technical Support: Fax: www.panduit.com/resources/install_maintain.asp www.panduit.com...

This manual is also suitable for:

Cjrw seriesCjry seriesMini-com series110 seriesP110rc2Cjsv series