INSTALLATION INSTRUCTIONS
IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR
SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.
The LS1 Series of commercial and industrial LED fixtures is designed to be used in utility strip applications using suspension or
surface mount installation. The LS1 Series is designed for use in 120 – 277V, 50/60Hz protected (max 20A) circuits.
Size line voltage Service wire as required per the National Electric Code (NEC).
4' LINEAR STRIP FIXTURE (FXT)
ISOMETRIC VIEW
4' LINEAR STRIP FIXTURE
LINKING (LNK) ISOMETRIC VIEW
GENERAL NOTES:
FIXTURES ARE ALL 4' SECTIONS. EACH FIXTURE HAS 1 DRIVER.
1.
MAKE SURE ALL WIRES AND CONNECTORS ARE UL-LISTED. IF THE
2.
ELECTRICAL SYSTEM CONTAINS NO GROUND WIRE, CONSULT
WITH A QUALIFIED ELECTRICIAN BEFORE PROCEEDING WITH THE
INSTALLATION.
SUSPENSION CABLE, CHAIN OR CEILING JUNCTION BOX PROVIDED
3.
BY CONTRACTOR SHALL BE RATED TO SUPPORT WEIGHT OF
FIXTURE(S) – INCLUDING ALL ACCESSORIES AND OPTIONS.
AIRCRAFT SUSPENSION CABLE MAY BE ORDERED SEPARATELY
FROM FLEX LIGHTING SOLUTIONS OR OTHERWISE PROVIDED
BY CONTRACTOR.
FLEXLIGHTINGSOLUTIONS.COM
These instructions apply to the following part numbers:
LS10S-A1-03K-04-35/40/50-80-FR-FXT or LNK-[xxx]-10V
LS10S-A1-04K-04-35/40/50-80-FR-FXT or LNK-[xxx]-10V
LS10S-A1-05K-04-35/40/50-80-FR-FXT or LNK-[xxx]-10V
ITEMS NOT INCLUDED:
(BUT REQUIRED FOR INSTALLATION):
PERSONAL PROTECTIVE EQUIPMENT
ITEMS INCLUDED:
REFER TO SPECIFICATION SHEET FOR ALL POSSIBLE OPTIONS.
LIGHTING.TECH@FLEX.COM
888-799-5002 option 3 or 913-851-3000 option 3
SCREWDRIVER
PLIERS
SUPPLY CONDUCTORS (BUILDING LINE POWER)
RECEPTACLE (IF APPLICABLE)
LINEAR STRIP LED LIGHT FIXTURE (FXT OR LNK)
CORD AND PLUG (OPTIONAL; SOLD SEPARATELY)
MAY ALSO INCLUDE SOME OPTIONAL ACCESSORIES (IF
ORDERED)
LS1 SERIES
11-27-18

Advertisement

loading

Summary of Contents for Flex LS10S-A1-03K-04-35-80-FR-FXT

  • Page 1 LINEAR STRIP LED LIGHT FIXTURE (FXT OR LNK) AIRCRAFT SUSPENSION CABLE MAY BE ORDERED SEPARATELY • CORD AND PLUG (OPTIONAL; SOLD SEPARATELY) FROM FLEX LIGHTING SOLUTIONS OR OTHERWISE PROVIDED • MAY ALSO INCLUDE SOME OPTIONAL ACCESSORIES (IF BY CONTRACTOR. ORDERED) REFER TO SPECIFICATION SHEET FOR ALL POSSIBLE OPTIONS.
  • Page 2: Maintenance

    ÉLECTRIQUES. THESE INSTRUCTIONS DO NOT ATTEMPT TO COVER ALL INSTALLATION AND MAINTENANCE SITUATIONS. FOR MORE INFORMATION OR QUESTIONS REGARDING THE INSTALLATION OR USE OF THE ESSENTIALS FIXTURE, CALL 913-851-3000 OR EMAIL AT LIGHTING.TECH@FLEX.COM. MAINTENANCE LINEAR STRP FIXTURES SHOULD BE DRY DUSTED PERIODICALLY. THE FROSTED LENS CAN BE CLEANED WITH DAMP OR DRY CLOTH. NO SPECIAL CLEANER REQUIRED.
  • Page 3: General Instructions

    INSPECT PACKAGE(S) FOR SIGNS OF DAMAGE. NOTIFY CARRIER IMMEDIATELY IF FIXTURE PACKAGING IS DAMAGED. UNPACK THE FIXTURES FROM PACKAGING. RECYCLE AND PROPERLY DISPOSE OF PACKAGING. INSPECT FIXTURES. IF THERE IS ANY FIXTURE DAMAGE OBSERVED, TAKE PHOTOGRAPHS AND IMMEDIATELY CONTACT LIGHTING.TECH@FLEX.COM. TURN OFF ELECTRICITY AT THE MAIN CIRCUIT BREAKER, PANELBOARD, FUSE BOX OR DISCONNECT.
  • Page 4 SUPPORT FOR SECTIONS WHEN ONLY TWO CABLE MOUNTS ARE AVAILABLE. SECTION “8B” SECTION “8B” SECTION “8B” SECTION “8A” SECTION “8A” SECTION “8A” SECTION “8B” SECTION “8B” SECTION “8B” ENDCAP LS-MJP FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...
  • Page 5 ACCESSORY AND ATTACH A PLASTIC ENDCAP FROM ONE OF THE EXISTING LNK FIXTURES TO SEAL THE RUN. USE SCREWS PROVIDED TO SECURE END CAP, 1 ON EACH SIDE. 26. MAKE FINAL MOUNTING AND WIRING CONNECTIONS. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...
  • Page 6 11. LEVEL FIXTURE PLUMB WITH BUILDLING LINES. (TO LET OUT CABLE, PUSH PLUNGER DOWN). 12. MAKE FINAL WIRING CONNECTIONS. REFER TO “MAKING ELECTRICAL CONNECTIONS”. 3 POINT MOUNT 4 POINT MOUNT FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...
  • Page 7 PULL EXISTING AC POWER FROM BUILDING THROUGH KNOCKOUT LOCATION INTO FIXTURE HOUSING. PROVIDE UL APPROVED STRAIN RELIEF (NOT PROVIDED) AS REQUIRED. RAISE FIXTURE HOUSING TO SURFACE AND SECURE WITH APPROPRIATE CONNECTOR(S). MAKE FINAL WIRING CONNECTIONS. REFER TO “MAKING ELECTRICAL CONNECTIONS”. KO EXAMPLE LOCATION SECTION “A” FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...
  • Page 8: Making Electrical Connections

    REMOVE THE KNOCKOUT WITH A SCREWDRIVER. • PULL EXISTING AC POWER FROM BUILDING THROUGH KNOCKOUT LOCATION INTO FIXTURE HOUSING. PROVIDE UL APPROVED STRAIN RELIEF (NOT PROVIDED) AS REQUIRED. KO EXAMPLE LOCATION DRIVER KO EXAMPLE LOCATION FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...
  • Page 9 ATTACH LED LIGHT COVER BY RAISING IT TO THE CHASSIS AND SNAPPING IN PLACE. INSERT SAFETY SCREW (PROVIDED). REMOVE PLASTIC FILM FROM LENS. TURN ON ELECTRICITY AT THE CIRCUIT BREAKER, PANELBOARD, OR FUSE BOX. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...
  • Page 10 (HOT); WHITE TO WHITE (NEUTRAL) AND GREEN (OR BARE) TO GREEN (GROUND); VOILET TO VIOLET AND GREY TO GREY ON 5-WIRE CORD (IF APPLICABLE). FIXTURES WITH OPTIONAL FACTORY-INSTALLED CORD AND PLUG: CONNECT CORD AND PLUG TO NEAREST APPROPRIATELY RATED RECEPTACLE (PROVIDED BY CONTRACTOR). FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...
  • Page 11 TURN ON ELECTRICITY AT THE CIRCUIT BREAKER, PANELBOARD, OR FUSE BOX. HARDWIRED FIXTURES (LNK), CONT.: 10. (LNK) LINKING SECTIONS TOGETHER: • EACH LNK FIXTURE COMES WITH THE MECJHANICAL JOINING PIECE (LS-MJP) INSTALLED ON ONE END FOR MECHANICAL CONNECTION. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...
  • Page 12 PLUG SENSOR STOP (LS-SNSRSTOP) QUICK DISCONNECT FROM ONE SECTION INTO QUICK DISCONNECT ON THE NEXT SECTION. • CONTINUE INSTALLING FIXTURES UNTIL COMPLETE. TURN ON ELECTRICITY AT THE CIRCUIT BREAKER, PANELBOARD, OR FUSE BOX. JUMPER SENSOR STOP FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 888-799-5002 option 3 or 913-851-3000 option 3 11-27-18...