Advertisement

Quick Links

INSTALLATION INSTRUCTIONS
IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR
SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.
The LINEAR Series of commercial and industrial LED fixtures is designed to be used in utility strip applications using suspension or
surface mount installation. The LINEAR Series is designed for use in 120 – 277V, 50/60Hz protected (max 20A) circuits.
Size line voltage Service wire as required per the National Electric Code (NEC).
4' LINEAR STANDALONE FIXTURE
ISOMETRIC VIEW
4' LINEAR RETROFIT KIT
ISOMETRIC VIEW
GENERAL NOTES:
1.
MAKE SURE ALL WIRE AND CONNECTORS ARE UL-LISTED. IF THE
ELECTRICAL SYSTEM CONTAINS NO GROUND WIRE, CONSULT
WITH A QUALIFIED ELECTRICIAN BEFORE PROCEEDING WITH THE
INSTALLATION.
2.
SUSPENSION CABLE, CHAIN OR CEILING JUNCTION BOX PROVIDED
BY CONTRACTOR SHALL BE RATED TO SUPPORT WEIGHT OF
FIXTURE(S) – INCLUDING ALL ASSESSORIES AND OPTIONS.
AIRCRAFT SUSPENSION CABLE MAY BE ORDERED SEPARATELY
FROM FLEX LIGHTING SOLUTIONS OR OTHERWISE PROVIDED
BY CONTRACTOR.
FLEXLIGHTINGSOLUTIONS.COM
These instructions apply to the following part numbers:
LIGHTING.TECH@FLEX.COM
LINEAR SERIES
LR20S-Ax-xK-04-[xxx]-LV-FXT-[xxx]-10V
LR20S-Ax-xK-08-[xxx]-LV-FXT-[xxx]-10V
LR20S-Ax-xK-12-[xxx]-LV-FXT-[xxx]-10V
LR20S-Ax-xK-04-[xxx]-LV-RTR-[xxx]-10V
LR20S-Ax-xK-08-[xxx]-LV-RTR-[xxx]-10V
LR20S-Ax-xK-12-[xxx]-LV-RTR-[xxx]-10V
LR20S-Ax-xK-04-[xxx]-LV-RMW-[xxx]-10V
LR20S-Ax-xK-08-[xxx]-LV-RMW-[xxx]-10V
LR20S-Ax-xK-12-[xxx]-LV-RMW-[xxx]-10V
4' LINEAR RETRO
MULTI WIDTH KIT
(BACKBOX NOT INCLUDED)
ISOMETRIC VIEW
ITEMS NOT INCLUDED:
(BUT REQUIRED FOR INSTALLATION):
PERSONAL PROTECTIVE EQUIPMENT
SCREWDRIVER
PLIERS
SUPPLY CONDUCTORS (BUILDING LINE POWER)
RECEPTACLE (IF APPLICABLE)
ITEMS INCLUDED:
LINEAR LED LIGHT FIXTURE (FXT, RTR OR RMW)
CORD AND PLUG (OPTIONAL; SOLD SEPARATELY)
MAY ALSO INCLUDE SOME OPTIONAL ACCESSORIES (IF
ORDERED)
REFER TO SPECIFICATION SHEET FOR ALL POSSIBLE OPTIONS.
913-851-3000
11-13-17

Advertisement

Table of Contents
loading

Summary of Contents for Flex LINEAR LR20S-A Series

  • Page 1  RECEPTACLE (IF APPLICABLE) FIXTURE(S) – INCLUDING ALL ASSESSORIES AND OPTIONS. AIRCRAFT SUSPENSION CABLE MAY BE ORDERED SEPARATELY ITEMS INCLUDED: FROM FLEX LIGHTING SOLUTIONS OR OTHERWISE PROVIDED  BY CONTRACTOR. LINEAR LED LIGHT FIXTURE (FXT, RTR OR RMW)  CORD AND PLUG (OPTIONAL; SOLD SEPARATELY) ...
  • Page 2: Maintenance

    BOÎTIER DE CÂBLAGE OU DE COMPOSANTS ÉLECTRIQUES. THESE INSTRUCTIONS DO NOT ATTEMPT TO COVER ALL INSTALLATION AND MAINTENANCE SITUATIONS. FOR MORE INFORMATION OR QUESTIONS REGARDING THE INSTALLATION OR USE OF THE ESSENTIALS FIXTURE, CALL 913-851-3000 OR EMAIL AT LIGHTING.TECH@FLEX.COM. MAINTENANCE LINEAR FIXTURES SHOULD BE DRY DUSTED PERIODICALLY.
  • Page 3: General Instructions

    INSPECT PACKAGE(S) FOR SIGNS OF DAMAGE. NOTIFY CARRIER IMMEDIATELY IF FIXTURE PACKAGING IS DAMAGED. UNPACK THE FIXTURES FROM PACKAGING. RECYCLE AND PROPERLY DISPOSE OF PACKAGING. INSPECT FIXTURES. IF THERE IS ANY FIXTURE DAMAGE OBSERVED, TAKE PHOTOGRAPHS AND IMMEDIATELY CONTACT LIGHTING.TECH@FLEX.COM. TURN OFF ELECTRICITY AT THE MAIN CIRCUIT BREAKER, PANELBOARD, FUSE BOX OR DISCONNECT.
  • Page 4 PRESS CENTER BETWEEN SLOTS OF JOINER PIECE SO THAT SLOTS WILL INSERT THROUGH NOTCHES IN SIDE OF FIXTURE HOUSING. JOINER PIECE JOINER PIECE SECTION “8A” SECTION “8A” SECTION “8A” SECTION “8B” SECTION “8B” SECTION “8B”  FIXTURE IS NOW READY TO MOUNT. PROCEED TO THE APPROPRIATE APPLICABLE MOUNTING INSTRUCTIONS. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 5 FIXTURE IS NOW READY TO MOUNT. PROCEED TO THE APPROPRIATE APPLICABLE MOUNTING INSTRUCTIONS. STAND ALONE FIXTURE (FXT) – SUSPENSION MOUNT INSTRUCTION TO FOLLOW USES FLS HANGERKIT (SOLD SEPARATELY). HANGERKIT – ITEMS INCLUDED:  “Y” TOGGLE AND GRIPPER  LOOP CABLE. TOGGLE GRIPPER “Y” TOGGLE AND GRIPPER” LOOP CABLE FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 6 12. MAKE FINAL WIRING CONNECTIONS. REFER TO “MAKING ELECTRICAL CONNECTIONS”. 8’ SECTION: FOLLOW INSTRUCTIONS FOR “4FT SECTION”, NUMBERS 2 THROUGH 5 TO INSTALLED TOGGLE AND GRIPPER. 14. INSTALLING MIDDLE TOGGLE/GRIPPER FOR 3 HANGER POINTS: PRESS GRIPPER AGAINST CABLE SO GRIPPER AND CABLE ARE PARALLEL. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 7 26. PASS LOOP CABLE THROUGH TOGGLE. PLUNGER ON TOP OF TOGGLE CATCHES AND HOLDS CABLE SECURELY. 27. LEVEL FIXTURE PLUMB WITH BUILDLING LINES. (TO LET OUT CABLE, PUSH PLUNGER DOWN) 28. MAKE FINAL WIRING CONNECTIONS. REFER TO “MAKING ELECTRICAL CONNECTIONS”. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 8 IDENTITY FLUORESCENT FIXTURE BEING UPGRADED WITH LED RETROFIT KIT. TURN FLUORESCENT FIXTURE OFF AND ALLOW LAMPS TO COOL PRIOR TO STARTING WORK. IF FLUORESCENT FIXTURE HAS LENS OR DIFFUSER, REMOVE TO GAIN ACCESS TO LAMPS. TRADITIONAL FLUORESCENT FIXTURE FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 9 USING WIRE CUTTERS, REMOVE INSULATION ON WIRES APPROXIMATELY 3/8" FROM WIRE END. TAKE CARE NOT TO DAMAGE THE COPPER CONDUCTORS. RETROFIT KIT (RTR) INSTALLING KIT: REFER TO “PREPARING EXISTING FIXTURE FOR RETROFIT KIT (RTR) OR RETRO MULTI WIDTH KIT (RMW)”. REFER TO “MAKING ELECTRICAL CONNECTIONS”. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 10 EACH BRACKET IS SET UP IN 1/2” INCREMENTS (EACH SIDE). 3.25” ” 4.25” 5.25” 6.25” USING PLIERS, BEND APPROPRIATE TABS AT 90° SO IT CAN BE ATTACHED TO HOUSING WITH SELF TAPPING SHEET METAL SCREWS. BEND HINGE POINT AT 90° DOWN TOWARDS HOUSING (AS SHOWN). FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 11 SUCH A WAY IT DOES NOT INTERFERE WITH THE MECHANICAL OR ELECTRICAL PORTION OF THE INSTALLATION. 1/2” TO 1” 42 1/4” BETWEEN MATING HOOKS 1/2” TO 1” HANG LED LIGHT COVER FROM HINGE POINTS SO IT IS HANDS FREE. REFER TO “MAKING ELECTRICAL CONNECTIONS”. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 12: Making Electrical Connections

    CHOOSE A SUITABLE KNOCKOUT LOCATION FROM THOSE PROVIDED IN FIXTURE HOUSING. REMOVE THE KNOCKOUT WITH A SCREWDRIVER. PULL EXISTING AC POWER FROM BUILDING THROUGH KNOCKOUT LOCATION INTO FIXTURE HOUSING. PROVIDE UL APPROVED STRAIN RELIEF (NOT PROVIDED) AS REQUIRED. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 13 CARE NOT TO PINCH ANY WIRES. (FXT) 4FT SECTION: ATTACH LED LIGHT COVER TO FIXTURE HOUSING. ENSURE ALL WIRING IS SAFELY TUCKED INSIDE THE INTERIOR OF THE FIXTURE BEFORE FINALIZING INSTALLATION. ATTACH LED LIGHT COVER WITH SELF-TAPPING SCREWS (PROVIDED). FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...
  • Page 14 ALL SELF-DRILLING SCREWS (PROVIDED) THROUGH THE HOLES NEAR THE TABS IN THE LED HOUSING. (4) SCREWS TOTAL FOR 4FT SECTION, (8) SCREWS FOR 8FT SECTION, (12) SCREWS FOR 12FT SECTION. 14. TURN ON ELECTRICITY AT THE CIRCUIT BREAKER, PANELBOARD, OR FUSE BOX. RMW ONLY FXT, RTR ONLY FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEX.COM 913-851-3000 11-13-17...

Table of Contents