 IFB-244-SSC/IFB-244-MSC: 9~48V DC or 24V AC
Figure 4-6: IFB-244-SSC/IFB-244-MSC upper panel
2. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
Figure 4-7: PWR1 & PWR2 pins of terminal block.
The wire gauge for the terminal block should be in the
range from 12 to 24 AWG.
Note
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
sure the power is OFF to prevent from getting an electric
shock.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
V1+
V2+
PWR1
Fault
PWR2
1
2
3
4
V1+ V1-
Power 1
Fault
DC Input: 9-48V
, 0.5A max.
AC Input: 24V , 0.2A max.
5
6
V2+ V2-
Power 2