BWT Avanti RF Series Installation And Operating Manual

BWT Avanti RF Series Installation And Operating Manual

Manual backwashing filter dn 25 and dn 50 90 micron sediment filter complete with dual check valve backflow prevention device

Advertisement

Installation and operating manual
AUS
Suitability:
Suitable for domestic and commer-
cial installations to remove sedi-
ment and improve the service life
of plumbing fixtures and fittings.
Product Approval:
The product is certified to
ATS 5200.103
ATS 5200.103
LIC WM-020272
BWT Avanti RF
Manual backwashing filter
DN 25 and DN 50
90 micron sediment filter
complete with dual check valve
backflow prevention device

Advertisement

Table of Contents
loading

Summary of Contents for BWT Avanti RF Series

  • Page 1 Product Approval: The product is certified to ATS 5200.103 ATS 5200.103 LIC WM-020272 BWT Avanti RF Manual backwashing filter DN 25 and DN 50 90 micron sediment filter complete with dual check valve backflow prevention device...
  • Page 2: Scope Of Supply

    1 Scope of supply BWT Avanti RF Australia consisting of: Top section in DR brass Union connection fitting with seals 2a Union connection with dual check valve Transparent bowl with filter element Hose connection for flushing water supply Turning knob for the backwashing element The product is approved to ATS 5200.103;...
  • Page 3: Installation Conditions

    For the backwashing process, the waste water con- nection is opened by turning the turning knob (5) and the backwashing element is also turned. The particles on the filter cloth are removed by suction from the suction-ring backwashing system and then washed out.
  • Page 4: Installation

    5 Installation Install filter according to its nominal size in cold wa- ter pipes of the same dimensions and before the equipment to be protected. Install stop valves be- Σm fore and after the filter. 0 0 0 Assemble the connection fittings (2) in the pipe and install filter in flow direction (see flow direction ar- row) in the horizontal cold water pipe (see instal- lation sketch).
  • Page 5: Operation

    7 Operation A backwash must be carried out as required to pre- vent dirt particles from settling on the filter cloth (or more frequently with higher amounts of dirt). Before starting the backwash procedure, provide a collecting basin, if the flushing water pipe is not connected to the waste water drain.
  • Page 6: Troubleshooting

    8 Trouble-shooting Fault Cause Solution Water pressure in system has Dirty filter element Carry out backwash dropped considerably; Water pressure drops consider- ably when water is bled (by more than 35% of the stat- ic pressure) Flushing water outlet cannot Backwash element does not Fully open and close turning be closed...
  • Page 7: Specifications

    9 Specifications BWT Avanti RF Type 1“ 2“ Nominal connection size Hose connection, diameter Flow rate at ∆p = 20 kPa 10,0 Flow rate at ∆p = 50 kPa 15,5 Filter screen µm 90/110 Nominal pressure (PN) Water temperature °C 5 - 30 Ambient temperature, max.
  • Page 8 Further information: Reece. Works for you. ™ Call 1800 032 566 or visit www.reece.com.au for your nearest Reece store. Due to limitations in the printing process the colours in this brochure are a guide only. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification.