Chimney Requirements - Olsberg Virgo Installation Instructions Manual

Cylindrical stove
Table of Contents

Advertisement

1.0 USER INSTRUCTIONS
1.4 - Health & Safety Cont.
Olsberg stoves are freestanding stoves that cannot be equipped with an individual cover or be built in as a
fire chamber insert/cassette. You must not make any modifications influencing the operation of the stove.
Remove all packaging and supporting materials from the chamber and all accessories from the ash drawer
and the wood case. Make sure that the lining of the fire chamber and all pieces of the dead plates are in
the correct place and fitted correctly. Do not use the stove without these components. Take care as the
packaging material can contain nails and other sharp pieces of metal, which can cause injury to you and
the stove. Take care that the nylon and other wrapping materials do not get in children's hands, as they can
cause suffocation. Carefully collect the packaging materials mentioned above, and take them to the local
waste disposal site.
The stove is painted in high temperature paint and high quality heat resistant lacquer that gains its final
stability when heating up for the first time. The smell at the first heating up derives from the evaporation of
the protecting lacquer in the paint. So the heated room must be carefully ventilated from time to time (every
1-2 hours). The smell will stop after a while of burning.
Do not put anything on the stove before the first heating
up and do not touch its surface to prevent damage of
lacquering. Use protective gloves for your own protection
and for the sake of the intactness of the lacquering.
The doors of the stove should be kept slightly open during
the first heating up so the insulation cord does not stick to
the front of the stove.

1.5 - Chimney Requirements

The chimney design is according to DIN EN 13384-1 and -2 or to the specific national regulations. The
chimney must comply with the temperature class T400.
Necessary data
Closed operation with wood
• Nominal thermal output ............................................................................ 5,5 / 5,5 kW
• Waste air mass ow rate ............................................................................. 5,5 / 5,5 g/s
• Waste air temperature ............................................................................... 260 / 260 °C
• Minimum delivery pressure at nominal thermal output.............................13 / 13 Pa