4.0 TROUBLESHOOTING

3.6 - After Use & Maintaining Perfect Burn Cont.
Combustible remains are deposited in the appliance, the flue and chimney during use. This happens
increasingly if you use wet or treated wood or fuel that is not allowed. The possible overload of the stove or
restrain of the fire can contribute to this also. It is rare that the deposits catch fire due to the lack of regular
cleaning. However, this can be noticed from the black smoke flowing out of the chimney, the rise of the
temperature of the chimney wall and the increased draught that can result in a whistling sound.
In case of chimney fire, call the fire brigade and close all air regulators and outlets. Do not spray or pour
water in the chimney in any case because it can lead to gas explosion. Remove all combustible, heat
sensitive materials from the environment of the chimney, even in the attic.

4.1 - General Troubleshooting

The condition of proper operation of the stove is the appropriate chimney draught (feed pressure). This is
considerably dependant on the temperature of the outer environment. In case of higher outer temperature
(above 15oC) feed pressure can considerably fall and it can disturb proper operation.
What can you do?
- Open the primary air regulator a bit more and fully open the secondary air regulator
- Use only a small amount of fuel at first
- Use only a small amount of fuel when reloading
- Riddle & Grate
What are the causes?
• There is no proper draught at heating up
- Chimney or stove pipe is not closed properly
- Measurements of the chimney are not appropriate
• The space is not heating up?
- The appliance is disproportionally small
- There is too much ash in the combustion chamber
- The air regulator is closed
• The stove gives off too much heat?
- The air regulator is opened too far
- The chimney draught is too high
- Loading too much fuel
• The bottom grate is damaged?
- The stove has been overloaded
- The ash drawer wasn't emptied in time
- Chimney draught is too high
PAGE 16