Amana 18 Cu. Ft Service page 51

Bottom mount refrigerators
Table of Contents

Advertisement

17. Reverse door stop.
• Locate door stop on bottom end of door.
• Remove two mounting screws. Move door stop to
current hinge side and replace screws.
Freezer and
refrigerator doors
Door stop
Relocate Door Stop
18. Replace end caps.
• Put end caps in place. Replace screws.
• If end caps rattle after tightening, remove them;
put double-sided tape under them, and replace
them once again using screws.
19. Set fresh food door aside and place freezer door on
protected surface.
20. Remove end caps from freezer door.
• Remove screws from cap on each end of door.
• Move button plug to hole at side opposite.
21. Perform steps 12 through 20 on freezer door.
22. Remount both doors by reversing steps 1 through 9.
Screws
Installation Instructions
Water Supply
!
To avoid risk of electrical shock which can cause
severe personal injury or death, disconnect power to
refrigerator before connecting water supply. After
connecting water supply, connect power.
!
To avoid property damage, make sure water supply
is connected per instructions below.
1. Connect water supply.
a. Get a licensed plumber to connect shut-off valve
and water-supply tube to household plumbing in
compliance with local codes.
NOTE: Use only seamless, flexible, 1/4" (6 mm) copper
tubing. Tubing must be long enough to reach
from water supply to refrigerator connection plus
an additional 8' (2.4 M) with which to form
service loop behind refrigerator.
NOTE: The correct type of shut-off valve requires that a
1/4" (6 mm) hole be drilled in the household
water pipe before the valve is attached. Do not
use a self-piercing shut-off valve or a valve of
any size other than 1/4" (6 mm). Amana is not
responsible for property damage caused by
improper water connection.
!
To avoid property damage, have towels ready to soak
up spillage before attempting the rest of these steps.
b. Confirm that water pressure at refrigerator end of
water-supply line is between 20 psi and 100 psi
(between 1.4 and 7.0 kg/cm
NOTE: Units with filter require pressure between 35 psi
and 100 psi (2.5 and 7.0 kg/cm
NOTE: Water valve in your refrigerator will not work
properly if system pressure is not within spec.
c. Remove plastic cap from water-valve inlet port on
back of refrigerator. Place brass nut and brass
ferrule on copper water-supply tube.
B - 9