Time to Charge
Optional Backup Battery Pack
Time to Charge (optional backup
battery pack)
Wired Detectors Total (Sum) Current
Site External Siren Current (EXT)
Site Internal Siren Current (INT)
PGM
High Current / Short Circuit
Protection

A4. Communication

Communication
Built-in Modem
Data Transfer to Local Computer
Report Destinations
Reporting Format Options
Pulse Rate
Message to Private Phones
Ring Detection

A5. Physical Properties

Operating Temp. Range
Storage Temp. Range
Humidity
Size (WxHxD)
Weight
Color

A6. Peripherals and Accessory Devices

Modules
Additional wireless devices
Wireless Devices and peripherals
D-306048
WP8033 Installer's Guide
(1) The external devices must be connected between 12V and ground. The current
for each specified backup period can be drawn from the batteries with the
internal GSM and the proximity reader connected to the WP8033.
(2) 7.2V 1300 mAh, rechargeable NiMH battery pack, p/n 130AAH6BMX,
manufactured by GP or p/n LTT-AA1300LSDX6B, manufactured by LTT.
(3) 9.6V 1800 mAh, rechargeable NiMH battery pack, p/n GP180AAH8BMX,
manufactured by GP or p/n LTT-AA1800LSDX8B, manufactured by LTT.
(4) 9.6V 2200 mAh, rechargeable NiMH battery pack p/n 220AAH8BMX,
manufactured by GP or p/n LTT-AA2200LSDX8B, manufactured by LTT.
Caution! Risk of explosion if battery is replaced by an incorrect type. Dispose of
used batteries according to the manufacturer's instructions.
Notes:
1. For compliance with CE standards the battery backup period must be at least 12 hours
2. For compliance with UL standards the battery backup period must be at least 24 hours
80 % ( 30 Hrs) for all battery types
See "Backup Battery Options" table above
NA
36* mA max.
450* mA max @ 12.5 VDC when powered by AC/DC (10.5 VDC when in standby mode)
450* mA max @ 12.5 VDC when powered by AC/DC (10.5 VDC when in standby mode)
*
Total WP8033 output current (of INT & EXT sirens, PGM output and detectors)
cannot exceed 550 mA.
Current sink to control panel GND 100 mA max.
Max. external DC voltage +15 VDC
All outputs are protected (automatic reset fuse)
PSTN; GSM; GPRS; IP
300 baud, Bell 103 protocol
Via RS232 serial port
2 Monitoring Stations, 4 private telephones
SIA, Contact ID, Scancom, SIA IP, DSC PowerNet.
10, 20, 33 and 40 pps - programmable
Tone or voice
The unit does not support ring detection without DC voltage present on the telephone lines
-10°C to 49°C (14°F to 120°F)
-20°C to 60°C (-4°F to 140°F)
85% relative humidity, @ 30°C (86°F)
266 x 201 x 46 mm (10-7/16 x 7-7/8 x 1-13/16 in.)
1.44Kg (3.2 lb) (with battery)
White
GSM/GPRS, IP
64 detectors, 32 keyfobs, 32 keypads, 8 sirens, 4 repeaters , 32 proximity tags
Magnetic Contact: PGx99945, PGx9975
Motion Detectors: PGx9904; PGx9904P, PGx9984, PGx9984P, PGx9974,
PGx9974P, PGx9994, PGx9944, PGx9924
PIR Camera Detectors: PGx9934; PGx9934P
Smoke Detector: PGx9926, PGx9916
GSM Module: GSM-350
Keyfob: PGx9939, PGx9929
Keypad: WK141 (with proximity tag), WK160
Indoor Siren: PGx9901
Outdoor Sirens: PGx9911, PGx9911
Repeater: PGx9920
Gas: PGx9913
Glass-break: PGx9912
Temperature: PGx9905
Shock: PGx9935