Safety - Honeywell Sensepoint XCD RFD Technical Handbook

Remote flammable detector
Hide thumbs Also See for Sensepoint XCD RFD:
Table of Contents

Advertisement

Sensepoint XCD RFD Technical Manual

1 Safety

Ensure that this Operating Manual is read and understood BEFORE installing / operating
/ maintaining the equipment. Pay particular attention to Warnings and Cautions. All
document Warnings are listed here and repeated where appropriate at the start of the
relevant chapter(s) of this Operating Manual. Cautions appear in the sections/sub-sections
of the document where they apply
Sensepoint XCD RFD is designed for installation and use in Zone 1 or 2 hazardous areas in
many countries including Europe, and for Class I, Division 1, Groups B, C & D Hazardous
Installation must be in accordance with the recognized standards of the appropriate
Access to the interior of the detector, when carrying out any work, must only be conducted
Before carrying out any work ensure local regulations and site procedures are followed.
Appropriate standards must be followed to maintain the overall certiication of the detector.
If using an anti-seize compound, the threads should be thinly coated with an approved
To reduce the risk of ignition of hazardous atmosphere, de-classify the area or disconnect
the equipment from the supply circuit before opening the detector enclosure. Keep
Never attempt to open a junction box/enclosure or replace/reit the sensor in potentially
hazardous atmospheres while power is still applied to the transmitter.
The detector must be earthed/grounded for electrical safety and to limit the effects of radio
frequency interference. Earth/ground points are provided inside and outside the unit. The
internal grounding shall be used as the primary equipment ground. The external terminal is
only a supplemental bonding connection where local authorities permit or require such a
Ensure that all screens/instrument earth/clean earth wiring is earthed/grounded at a single
point (either at the controller or detector - BUT NOT BOTH) to prevent false readings or
alarms that may occur due to potential earth/ground loops.
Take care when handling sensors as they may contain corrosive solutions.
Do not tamper with or in any way disassemble the sensor.
Do not expose to temperatures outside the recommended ranges.
Do not expose sensors under storage conditions to organic solvents or lammable liquids.
Refer to the local or national regulations relative to the installation at the site. For Europe
This equipment is designed and constructed as to prevent ignition sources arising, even
in the event of frequent disturbances or equipment operating faults. Note: The control card
The sensor head must be itted with the supplied weather protection, and mounted so that
the sinter is pointing downward to provide ingress protection IPX6.
The weather protection is a potential electrostatic charging hazard. The manufacturer's
For Safety reasons, this equipment must be operated and serviced
(Pour des raisons de securite, Cet equipment doit etre utilise,
Any rapid upscale reading followed by a declining or erratic reading may indicate
a gas concentration beyond the upper scale limit which may be hazardous.
WARNINGS
Areas in the Americas.
authority in the country concerned.
by trained personnel.
silicone free compound e.g. petroleum jelly
assembly tightly closed during operation.
connection.
see EN60079-29-2, EN60079-14 and EN61241-14.
Only assessed for ATEX for ignition hazards.
must have a suitably rated fuse.
instructions should be observed.
by qualified personnel only
Entretenu et repare uniquement par un personnel qualifie)
EMI signal may cause incorrect operations.
SPXCDHMRFEN Issue 4_08-2016