Grundfos DP and EF wastewater pumps are portable and designed for pumping domestic and industrial wastewater. Two types of pumps are available: • DP 10.50 and DP 10.65 drainage pumps Fig. 3 EF 30.50 pump • EF 30.50 effluent pump. Explanation to figures 1, 2 and 3: The pumps are designed for free-standing installa- tion.
4. Installation 1.1 Applications DP 10 pumps are designed for pumping The loose nameplate supplied with the pump should • drainage and surface water be fixed at the installation site or kept in the cover of this booklet. • groundwater All safety regulations must be observed at the instal- •...
CU 100 control box, or If the pump is installed in muddy conditions or on un- • a Grundfos LC/D 107, LC/D 108 or LC/D 110 even ground, it is recommended to support the pump pump controller.
See fig. 4 or 5 and the installation and operating in- • The start level switch should be installed in such structions for the selected control box or pump con- a way that the pump is started at the required troller.
They must be connected to the 7. Check whether the system has been filled with Grundfos LC/D 108 pump controller via the liquid and vented. The pump is self-venting. intrinsically safe LC-Ex4 barrier to ensure 8. Start the pump.
Except for service on the hydraulic part, all other service work must be carried out by If the direction of rotation is wrong, interchange any Grundfos or an authorized service two of the incoming supply wires, see fig. 4 or 5. workshop.
7.1 Inspection intervals 6. Rotate the impeller by hand to check that it is not touching the wear plate. Pumps running normal operation should be checked 7. DP pumps only: Fit the suction strainer and at least once a year, but at least after 3000 operating tighten the screws (pos.
If it is worn and must be replaced, the pump and that the oil screws are pointing upwards. must be checked by Grundfos or an authorized 2. Fill oil into the oil chamber through the upper hole service workshop.
If Grundfos is requested to service the pump, Grund- fos must be contacted with details about the pumped liquid, etc. before the pump is returned for service.
1. Use the local public or private waste collection service. 2. In case such waste collection service does not exist or cannot handle the materials used in the product, please deliver the product or any haz- ardous materials from it to your nearest Grundfos company or service workshop.
For short periods up to +60°C. Explosion-proof pumps must never pump liquids with a temperature higher than 40°C. Density of pumped liquid Maximum 1100 kg/m³. In the case of higher values, contact Grundfos. Installation depth Maximum 10 metres below liquid level. Subject to alterations.