Asm Status - Siemens MOBY I ASM 421 Technical Description

Interface module
Table of Contents

Advertisement

6GT2 097-3AH00-0DA2
3.4.11

ASM STATUS

The ASM STATUS command provides information from the file handler. The command can be used to
look for errors. It shows the telegram traffic performed by the ASM 421.
Telegram to the file handler:
0
1
2/3
4
5
6/7
CC CI
ADB
xx 00 0000
'S'
'I'
0001
Acknowledgement:
0
1
2/3
4
5
6/7
CC Status ADB DBN DBL
00 xx 0000
'S'
00
0001
*
Only the data are valid that pertain to the telegram header.
The data in the telegram can have any content.
Subject to change without notice!
RD: 03/02
J31069-D0142-U001-A0-7618
8/9
10
DBN DBL
0001 00
8/9
10
11/18
19/44
0001 3DH
Vers. no.
Last instruction
26 bytes:
Version ident. of the file handler; 8 bytes ASCII
– 38 –
ASM 421 Technical Description
45/70
71
Last ack.
Connection status
Status information regarding state
of SLG hardware (24 V supply
present; fuse OK; cable to SLG OK;
SLG OK)
00H
Connection to SLG is OK
01H
Fault in connection to
SLG
26 bytes:
byte 0 to byte 25 of the acknowledge-
ment of the last command *
byte 0 to byte 25 of the last command to the ASM *
6GT2 002-0DA00
6GT2 002-0DB00
6GT2 002-0DC00
ASM 421 / V.24
ASM 421 / RS422
ASM 421 / TTY