Siemens MOBY I ASM 421 Technical Description page 64

Interface module
Table of Contents

Advertisement

6GT2 097-3AH00-0DA2
The following table contains a summary of all the errors from the ASM 421:
flashes of
red LED
A0 06
Unknown error, the command code CC is invalid
A0 11
DBN not equal to 1 in first command block; CC or DBN incorrect for subsequent blocks;
DBL is wrong or does not fit the transferred data length.
R
A0 15
eserved
A0 16
Command from another user being processed
B0 01
Fault in connection to the SLG
3
B0 02
1. Error when EAKO = 1; no MDS present (Timeout)
2. New MDS in transmission window; no NEXT command but command started (EAKO = 0,2)
3. New MDS has left station without NEXT (EAKO = 0,2)
4. EAKO = 2: MDS entry detected; however no MDS is to be found within the transmission
window
B0 05
EAKO = 3: An MDS has exited the transmission window without having entered it previously.
B0 06
EAKO = 3: new MDS arrives while the old one is still in the transmission window
B0 07
EAKO = 3: 2 x MDS entered without one having exited
C0 02
RAM error in MDS
4
2
C0 06
Proximity error
5
C0 07
Incorrect parameters in TRACE or FORMAT / command cannot be interpreted
C0 08
Too many sync attempts
6
C0 09
Too many send errors
7
8
C0 10
CRC send error
C0 11
reserved
C0 12
FORMAT, cannot initialize MDS
10
C0 13
FORMAT, timeout
11
12
C0 14
FORMAT, not initialized
C0 15
CMD address error
13
C0 16
ECC error
14
C0 17
General driver error
15
D0 01
Only RESET command permissible
1
D0 05
Invalid file or volume name
D0 07
The directory specified in the LOAD command is invalid; MOVE command isn't possible
D0 09
Incorrect parameter in RESET command
D0 14
CREATE and WRITE: the user data area in the MDS is full
D0 15
Only FORMAT command possible; MDS not identified
D0 18
Start address in the command is outside the data area (start address > file length)
D0 22
Directory and/or FAT-changing access to an MDS protected with COVER is illegal.
D0 23
COVER: MDS name is incorrect.
E0 01
The MDS type is incorrect or unsuitable for the selected mode of operation (ECC).
E0 02
CREATE command; no more directory entries available
E0 03
CREATE command; file already exists in directory
E0 05
FAT block error detected in READ or WRITE; FAT is incorrect.
F0 01
Specified data not present
F0 05
WRITE error in file with "Read only" or "Write once" attribute
F0 06
Incorrect access rights or switch setting
Kx xx
1. xxx = Number of the incorrect filr entry (See QUEUE-WRITE).
2. QUEUE-WRITE command in parameterized incorrectly.
3. The file to be set up already exists.
––––
The ASM has a receive error
27
––––
The ASM has a send error
28
*
Errors with no digits in this column do not cause the red LED to flash.
Subject to change without notice!
RD: 03/02
J31069-D0142-U001-A0-7618
Error messages from the file handler
– 62 –
ASM 421 Technical Description
TASK-RELATED
METERIZATION
6GT2 002-0DA00
ASM 421 / V.24
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
Kind of
error
PROTOCOL
ERROR
SLG
ERROR
MDS
ERROR
ERROR
DIRECTORY-
RELATED
ERROR
FILE-
RELATED
ERROR
QUEUE
PARA-
SERIAL
INTERFACE

Advertisement

Table of Contents
loading

Table of Contents