4 INSTALLATION
4.3

Mains supply

NOTE!
Mains supply requirements
This equipment complies with IEC 61000-3-12 provided that the short-circuit power is
greater than or equal to S
the public system. It is the responsibility of the installer or user of the equipment to
ensure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power greater than or
equal to S
scmin
The power source is delivered with a 4×2.5 mm2 mains cable and 16 A mains plug which in
combination can handle the rated data given for 3-phase 380–415 V mains supply.
1.
Rating plate with supply
connection data
Recommended fuse sizes and minimum cable area
Mains voltage
Input current at maximum output
Maximum recommended fuse
breaker rating
0463 605 001
at the interface point between the user's supply and
scmin
. Refer to the technical data in the TECHNICAL DATA chapter.
1)
or circuit
- 12 -
3~ 50/60 Hz
400 V ±10%
18 A
16 A
© ESAB AB 2018