Installation; Included Parts, Materials And Required Tools For Installation; Options; Assembly Details - Focus ERGOFOCUS Design Installation & Operating Manual

Hide thumbs Also See for ERGOFOCUS:
Table of Contents

Advertisement

Installation

INCLUDED PARTS, MATERIALS AND REQUIRED TOOLS FOR INSTALLATION

• Appliance and designated parts are the fire box, anchor plate, steel flue pipe, focus kit (protective glove, mounting
gloves, can of touch-up paint, ash removal hatch), and insulating washers.
• Required tools: drill, M8 allen key, level, screwdrivers, M12 key, scaffolding (up to underceiling height), refractory compound.
• 2 persons minimum are required for installation.

OPTIONS

• Custom ceiling cover disc (steel disc)
• Custom anchor steel plate (inclined...)
• Focus steel flue extension

ASSEMBLY DETAILS

A. STAINLESS STEEL CHIMNEY SYSTEM PLATE
SETUP AND CONNECTION
this point 3" mini.
below finished ceiling.
Ce niveau doit se trouver
75mm sous le plafond fini.
class A insulated chimney pipe
8" id - 10" od
cheminée isolée:
(200 int./250 ext.)
finishing collar
collier de finition
slip connector: same brand
as the class A insulated chimney.
adaptateur simple paroi de même
marque que la cheminée isolée
oblique anchor plate
platine de suspension inclinée
anti-heat loss washers
rondelles à rupture
de pont thermique
focus 8" universal adaptor
adaptateur focus
pour conduit en 200 mm
optional sub-ceiling
oblique cover disc
disque cache plafonnier
(optionnel)
focus steel flue
conduit en acier
• Adjustable suspension plate
• Rotation restrictor
B. FLUE ATTACHMENT TO ANCHOR PLATE
C. ORDER IN WHICH TO TIGHTENING THE PLATE
SCREWS (TO SECURE PROGRESSIVELY)
8 vis pointeaux
focus steel flue
conduit en acier
8