1st start-up
RIP 1
2nd restart
RIP 2
3rd restart
RIP 3
4th restart
RIP 4
Restart type
RIP F
Intervention time
RIP T
Hours running
ORE P
Exchange time
SCA T
1st start-up
SCA S
PWM frequency
FP
Anti-locking
TAB
52
Waiting time between the first lack of water reading and first
attempt to automatically restart the system (minutes). The module
will not attempt to restart if this parameter is set to zero.
Waiting time between the first restart and the second attempt to
automatically restart the system (minutes).
Waiting time between the second restart and the third attempt to
automatically restart the system (minutes).
Waiting time between the third restart and the fourth attempt to
automatically restart the system (minutes).
Parameter used to define how the restarting mechanism works. If
set to FIN, the module will go into a definitive alarm after the
fourth attempt. If sent to CICL, it will attempt to restart indefinitely
using the interval specified during the fourth attempt.
Waiting time after restarting within which pressure must return to
above the minimum threshold level for lack of water. (seconds)
Number of hours the pump has been running.
Parameter indicating the amount of time a pump must run for.
Once this value has been reached, the pump will stop and a
second pump will commence working. This parameter is
expressed in minutes until it reaches 60, after which it is
expressed in hours. The difference is indicated by the presence of
an "H" for hours and an "M" for minutes.
Must be set to primary for a unit or for twin pumps.
Waiting time between the first lack of water reading and first
attempt to automatically restart the system (minutes). The module
will not attempt to restart if this parameter is set to zero.
Frequency of the PWM which controls the motor.
Amount of time the pump is inactive. Once this amount of time
has expired, the pump will start up for 15 seconds at maximum
frequency. Then, the frequency will be slowly lowered until the
minimum set frequency is obtained. This parameter is expressed
in minutes until it reaches 60, after which it is expressed in hours.
The difference is indicated by the presence of an "H" for hours
and an "M" for minutes.
Page 22 of 23
22
22 - GB -
1
0
1440
5
0
1440
60
0
1440
720
0
1440
FIN
FIN
CICL
30
5
300
N.A.
x
xxxx
H 24
M 0
H 168
T 1
T 1
T 2
15.9
5.1
15.9
M 0
M 0
H 999