5. ANALOGUE SETTING In A
The default function is deactivated (In A=5).
To activate this function set In A <>5 and install the
potentiometer (as described in Chapter 3.5) or the command
with 0-5V. In this case, the set point for the head of the
pump will be reduced or increased based on the external
signal.
If (5<tEP<=9), delivery head for the pump will increase
between the minimum set value and the maximum value
which can be set as a set point value.
If (5<tEP<=9), delivery head for the pump will decrease
between the maximum set value and the minimum value
which can be set as a set point value.
Press "SET" to confirm. The symbol
seconds to show that the data has been saved.
46
disappears, the words "REC" will appear on the screen for a few
Page 16 of 17
16
16 - GB -