PREPARATIONS
Bypass
INSTALLATION STEPS
Determine the best location for your water Softener, bearing in mind the location of your water supply lines, drain line and 120 volt AC electrical
outlet. Subjecting the Softener to freezing or temperatures above 43°C (110°F) will void the warranty.
Please notice the inlet and outlet labels on the valve as shown here to
determine the position of the equipment:
Facts to Remember When Planning Your Installation
1. All installation procedures must conform to local and state or provincial plumbing codes.
2. Outside faucets used to water lawns and gardens should not supply untreated water, replace untreated water with feed water
to the unit. If necessary to do this please install check valve, see page 14. A new water line is often required to be connected to
supply untreated water to the inlet of the water filter and to the outside faucets.
3. Make sure the bypass is attached well to the control valve. Connect the straight or elbow connectors to the bypass with red
clips. Connect the inlet and outlet of the water filter to the plumbing of the house. The control valve must not be submitted
to temperatures above 43°C (110°F). When sweat fittings are used, to avoid damaging the control valve, solder the threaded
copper adapters to the copper pipe and then, using Teflon tape, screw the assembly into the bypass valve.
Do not use pipe thread compound as it may attack the material in the valve body.
4. Apply Teflon Tape and Orings to the fittings
5. Connect Filter to the house plumbing. Any solder joints near the valve must be done before connecting any piping to the valve.
Always leave at least 6" (152 mm) between the valve and joints when soldering pipes that are connected to the valve. Failure to
do this could cause damage to the valve.
6. Drain Line connection: Attach 5/8" OD drain hose (Supplied with some models and brands) to the hose barb and tighten
securely with a hose clamp (Supplied with some models and brands). Run the drain line to a floor drain or a laundry drain.
Complete any necessary plumbing.
7. Make sure there are no leaks in the plumbing system before proceeding.
2. Water Lines
Outside faucets used to water lawns and gardens should not supply softened water. A new water line is often required to be connected to supply hard water to the inlet of
the water softener and to the outside faucets. Cut the water line between where it enters the house and before any lines that branch off to feed the hot water heater or
other fixtures in the house and as near the desired location of the water softener as possible. Install a tee fitting on the feed end of the cut pipe, and an elbow fitting on the
other end. Install piping from the tee to the inlet of the water softener and from the elbow to the outlet of the softener. To sever the water lines which branch off to feed any
outside faucets, cut the branch lines approximately two inches from the fitting on the main water line. Install an elbow on the end of the pipe nearest the outside faucet and
a cap on the end connected to the existing water line. Install piping from the tee installed on the inlet line to the water softener to the elbow installed on the pipe to the
outside faucet. Following this procedure will result in all lines in the house, with the exception of the outside faucets, but including the water heater and therefore the hot
water lines, being supplied with soft water.
Attaching Bypass to Valve (If required in case of replacing the control valve. The new control
3.
Clips
valve comes with bypass attached)
Make sure the bypass is attached well to the control valve. Connect the straight or elbow connectors to
the bypass with red clips. Connect the inlet and outlet of the water Softener to the plumbing of the
house. The control valve must not be submitted to temperatures above 43°C (110°F). When sweat
fittings are used, to avoid damaging the control valve, solder the threaded copper adapters to the
copper pipe and then, using Teflon tape, screw the assembly into the bypass valve.Do not use pipe
thread compound as it may attack the material in the valve body.