Before Installation - NOVO EFC20 Owner's Manual

Table of Contents

Advertisement

BEFORE INSTALLATION

Make sure you have a copy of your most recent water test results. If your water has not been tested previously you can contact
your supplier of this product to obtain a water sample bottle to be sent to one of our facilities for a free analysis. It is important
that this product not be installed until you have this information.
In all cases where metal pipe was originally used and is later interrupted by poly pipe or the Noryl bypass valve or by physical
separation, an approved ground clamp with no less than #6 copper conductor must be used for continuity, to maintain proper
metallic pipe bonding.
Fig. 1.
Inspecting and Handling Your EconoFlo Softener*
Inspect the equipment for any shipping damage. If damaged, notify the transportation company and request a damage
inspection. Damage to cartons should also be noted.
Handle the filter unit with care. Damage can result if it is dropped or set on sharp, uneven projections on the floor.
Do not turn the filter unit upside down.
To Insure this Product Functions Properly:
Your feed water line size to the unit must be a minimum of 3/4 inch with an operating pressure of no less than 30
psi and no more than 125 psi.
MECHANICAL:
Do not use petroleum based lubricants such as petroleum jelly, oils or hydrocarbon based lubricants.Use only 100% silicone
lubricants (grease packet provided in parts kit). All plastic connections should be hand tightened only. Teflon tape may be used
on connections that do not use an O-ring seal. Do not use pliers or pipe wrenches except where indicated by Nut shape (eg. pipe
adapters) All plumbing must be completed according to local codes. Soldering connections should be done before connecting
any pieces to the pipe as excessive heat can damage them.
Tools Required for Installation:
NOTE: We recommend installation only be completed by a competent installer or
plumbing professional to insure this product is installed in accordance with local
plumbing codes.
s
Two adjustable wrenches
s
Additional tools may be required if modification to home plumbing is required.
s
Plastic inlet and outlet fittings are included with the filter. To maintain full valve flow, 3/4" or 1" pipes to and from the
filter fittings are recommended. You should maintain the same, or larger, pipe size as the water supply pipe, up to the filter
inlet and outlet.
s
Use copper, brass, or PEX pipe and fittings.
s
Some codes may also allow PVC plastic pipe.
s
ALWAYS install the included bypass valve, or 3 shut-off valves. Bypass valves let you turn off water to the filter for repairs if
needed, but still have water in the house pipes.
s
5/8" OD drain line is needed for the valve drain. A 10' length of hose is not included with some brands.
NOTE
All government codes and
regulations governing the
installation of these devices
must be observed.
CAUTION!
If the ground from the
electrical panel or breaker
box to the water meter or
underground copper pipe
is tied to the copper water
lines and these lines are cut
during installation of the No-
ryl bypass valve and/or poly
pipe, an approved grounding
strap must be used between
the two lines that have been
cut in order to maintain
continuity. The length of the
grounding strap will depend
upon the number of units
being installed and/or the
amount of copper pipe being
replaced with plastic pipe.
See Fig. 1.
NOTE
Check your local electrical
code for the correct clamp
and cable size.
NOTE
If a severe loss in water
pressure is observed when
the filter unit is initially
placed in service, the filter
tank may have been laid on
its side during transit. If this
occurs, backwash the filter
to "reclassify" the media.
*NOTE
11
Due to transportation
and climatic conditions all
connections including the
valve to the tank need to be
checked at time of
installation and tightened if
necessary.