GTN 6XX
4
ETHERNET IN 3
ETHERNET OUT 3
1. ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED.
2. GROUND DESIGNATIONS:
3. AT THE GTN 6XX, CONNECT SHIELD GROUNDS TO THE CONNECTOR BACKSHELL -- THE SHIELD
LEADS MUST BE LESS THAN 3.0". CONNECT THE SHIELD GROUNDS AT THE GDL 69/69A TO ITS
CONNECTOR BACKSHELL IN ACCORDANCE WITH THE GDL 69/69A INSTALLATION
INSTRUCTIONS.
4. ANY ETHERNET PORT MAY BE USED IN LIEU OF ETHERNET PORT 3. IF THERE ARE NO FREE
PORTS ON THE GTN 6XX, THE OTHER LRU CAN BE DISCONNECTED FROM THE GTN 6XX AND
THE GDL 69/69A CAN BE CONNECTED TO THE GTN 6XX IN ITS PLACE. THE DISCONNECTED
LRU CAN BE CONNECTED TO ETHERNET PORT 2, 3, OR 4 ON THE GDL 69/69A.
5. USE AIRCRAFT GRADE CATEGORY 5 ETHERNET CABLE. THESE INCLUDE THE FOLLOWING:
6. ETHERNET PORTS 2, 3, OR 4 MAY BE USED LIEU OF PORT 1. THE PORT THAT IS USED MUST
BE ENABLED IN CONFIGURATION MODE. REFER TO THE GDL 69/69A INSTALLATION MANUAL
FOR ADDITIONAL DETAILS.
Page D-22
Rev. C
P1002
A
23
B
24
A
25
B
26
s
s
SHIELD BLOCK GROUND
MANUFACTURER
PIC WIRE AND CABLE
ELECTRONIC CABLE SPECIALIST
Figure D-12. GTN - GDL 69/69A Interconnect
5
25
24
23
22
s
AIRFRAME GROUND
P/N
10424 (24 AWG)
392404 (24 AWG)
GTN 625/635/650 TSO Installation Manual
GDL 69/69A
A
ETHERNET OUT 1
B
A
ETHERNET IN 1
B
6
190-01004-02