Si06-763

6. Removal of the Fan Rotor / Fan Motor

Procedure
Step
1
For removal of the
drain pan, disconnect
the drain hose, then
loosen the 2 screws
located at left and right
sides.
2
Remove the drain pan.
3
To remove the swing
motor on discharge
port of the drain pan,
loosen the 2 fixing
screws.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Removal of the Fan Rotor / Fan Motor
Points
Be careful not to wet the
floor with drain water.
(R2637)
Disengage harness for drain
pan from right side hook.
This swing motor is for down
(R2638)
flow shutter.
Distributing louver