OT H E R F U N C T I O N S :
A U TO M AT I C T U R N O F F
After 4 hours of continuous working from the last function selection, the appliance turns off and
closes automatically.
G R E A S E F I LT E R S S AT U R AT I O N
After 30 hours of working, the speed indicators "D" will all flash simultaneously, signalling the
grease filters saturation.
To reset this alarm, hold down the "TIMER"button for at least 3 seconds, while the carriage is
open.
C A L I B R AT I O N
The cooker hood carries out its self calibration every 3 complete cycles of its extractable unit.
By pushing the "TIMER" key 6 times consecutively (MAX break between one push and the other
is 3 sec.) all the LED's will flash and the calibration will be reset.
After the next 3 cycles the downdraft will carry out its self calibration.
S TA N D - B Y
When the extractable unit is closed and the light is switched off, the control panel, after 6 seconds,
activates the stand-by function, reducing the brightness of the LED's.
This function can be stopped by pressing ON/ OFF or LIGHT key.
S E C U R I T Y S A F T E Y S YS T E M :
If there is an obstacle while the extractable unit is closing, the Downdraft stops closing and rises
again thanks to a security system.
W A R N I N G
This operation has to be carried out by a specialised technician.
14
Instruction manual DD911BK
Please keep this instruction manual for future reference
T I M I N G
As a result of the new EU65 "Energy label"and EU66 " Ecodesign" regulations issued by the
European Commission, which came into force as from January 1st, 2015 , our products have
been adapted to comply with these new requirements. All of the models complying with the
energy label requirements, are equipped with new electronics including a timer device for suction
speed control, when the air capacity exceeds 650m³/h. Internal motor models, with maximum
air capacity higher than 650m³/h, are equipped with a timer device that automatically switches
the suction speed from 4th to 3rd speed, after 6 minutes operation. External motor models are
equipped with remote motors that as with internal motor versions, include a timer device that
switches down the suction speed when it exceeds 650m³/h. (See External Motors Instructions)
Remote motors, whose air capacity exceeds 650m³/h at both 4th and 3rd speed, will have the
following by default timer control functions: The suction speed is automatically switched from
4th to 2nd speed, after 6 minutes operation. If the appliance is working at 3rd speed, it is
automatically switched to 2nd speed after 7 minutes operation. Operation speeds can also be
changed during operation. The energy consumption of the appliance in standby mode is lower
than 0.5W.