Fermax LOFT COMPACT 4+N COLOUR User& Installer's Manual page 15

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
Wiring
1
2
3
4
6
+
-
V
M
V
P2
P6
Ct
F1
F2
T A
1,2,3,6:
common audio wires
4: call wire
+, -: power supply (18 Vdc)
V: live (coaxial - video)
M: mesh (coaxial - video)
NOTES:
- A maximum of 100 monitors can be installed on a 4+N system.
- To connect an additional monitor in the same residence a call multiplier must be
added Ref. 2340.
P2
P6
T A
1 2
3
1
2
3
4
6
+
-
V
P1
M
V
Ct
F1
F2
+ -
4
6
CT COAX
Ct: Camera Activation (10 Vdc)
A, +: Call Extension
T, - : Residence Call Button
F1, F2: Additional Functions (negative output «-»)
Maximum current per F1 and F2 buttons: 50mA at 12Vdc
Call Extension
P1 (T, - ): Residence Call
A, +: Call Extension
DISTRIBUIDOR VIDEO 2 SALIDAS
REF.2448
2 OUTPUTS VIDEO DISTRIBUTOR
+
1
5
2
R
(-)
4
3
V
M
V
M
+18
V
M
R1
75
Button
6
V
M
Pag 15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents