Environmental Conditions - Siemens SIMATIC IPC327E Operating Instructions Manual

Table of Contents

Advertisement

Graphics
Graphics controller
Resolution, graphics memory
Ports
COM
USB
LAN interface X1
P1, RJ45
LAN interface X2
P1, RJ45
Keyboard, mouse
In BIOS Setup, you can configure support for RS 232/ RS 422/ RS 485 for COM1 and COM2
1
ports.
7.4.2

Environmental conditions

Climatic ambient conditions
For permitted mounting positions, see section Preparing for installation (Page 16).
Temperature, tested in accordance with IEC 60068-2-1, IEC 60068-2-2 and IEC 60068-2-14
Operation, USB load max. 10 W, mini card
load max. 2 W:
Temperature during storage/transport
Gradient
Relative humidity, tested in accordance with IEC 60068-2-78, IEC 60068-2-30
Operation
Storage/transport
Atmospheric pressure
Operation
Storage/transport
SIMATIC IPC327E
Operating Instructions, 06/2019, A5E40965257-AD
Integrated Graphic Controller
at least support 2 channels: 1 x VGA(DB-15) + 1 x DP(DDI)
32bit, support from 640*480 pixels to 1920*1200 pixels
RS 232 , max. 115 Kbps, D-sub connector, 9-pin
RS 232 /RS 422 /RS 485
USB 2.0, high speed/high current,
USB 3.0, high current
You can find additional information in the section Power demand of the compo-
nents (Page 54)".
Intel Ethernet Controller I211-AT
10, 100, 1000 Mbps
Intel Ethernet Controller I211-AT
10, 100, 1000 Mbps
Connection via USB port
1080 to 795 hPa, corresponds to an elevation of -1000 to 2000 m
1080 to 660 hPa, corresponds to an elevation of -1000 to 3500 m
(optional), max. 115 Kbps, D-sub connector, 9-pin
1
0 °C to +40 °C applies to device for all permitted
mounting positions
0 °C to +50 °C applies to device for all permitted
mounting positions for SSD configuration
-20°C to +60 °C
Operation: Max. 10 °C/h
Storage: 20 °C/h, no condensation
5% to 85% at 30 °C, no condensation
5% to 95% at 25/55 °C, no condensation
Technical specifications
7.4 Technical data