Texas Instruments UCD3138PSFBEVM-027 User Manual page 37

Table of Contents

Advertisement

www.ti.com
12.4.6.3
Constant Power and Constant Current Operation
Both hardware and firmware in this EVM support CPCC operation.
output voltage and output current (V
The EVM is delivered already programmed with a constant-power threshold of a few watts over 360 W
and a constant-current threshold of 33 A (typical). These limits are adjustable through the GUI and a new
setting can be saved to data flash. The maximum hardware capability limits the current within 35 A. The
dashed lines represent exceeding the constant power to a higher current, although the maximum current
of this EVM is limited to 35 A.
In addition to setting the previously described thresholds, enabling or disabling the CPCC feature and
configuring a fault timer is also possible. Whenever the State Machine detects CPCC operation a timer
starts. If the timer reaches the time limit specified in
command toggles off and on again, or recycles the input power.
SLUUAK4 – August 2013
Submit Documentation Feedback
versus I
OUT
Figure 34
shows the GUI default values of these controls.
Figure 33. CCPCC Operation
Figure 34. CPCC Default Values Adjusted Through GUI
Copyright © 2013, Texas Instruments Incorporated
Description of the Digital Phase-Shifted Full-Bridge Converter
Figure 33
). The dashed lines represent an extended view.
OUT
Figure
34, the system latches off until the on
Using the UCD3138PSFBEVM-027
illustrates the behavior of the
37

Advertisement

Table of Contents
loading

Table of Contents