FujiFilm OPC-G1-DEV Manual page 30

Table of Contents

Advertisement

(3) Control Supervisor object (Class 29 hex.)
This object monitors the current run command settings and the running status of the inverter, and configures the
running-related settings.
Instance
Attribute
Name
1
03
Run1
04
Run2
05
NetCtrl
06
State
07
Running1
08
Running2
09
Ready
0A
Faulted
0B
Warning
0C
FaultRst
0F
CtrlFromNet
10
DNFaultMode Inverter reaction to DeviceNet
Description
Run forward command
Run reverse command
Switching run command
source
Current inverter status
Running forward
Running reverse
Inverter ready to run/
Inverter running
(Synchronized with State
above)
Tripped state
Warning. Fixed at 0.
Reset of tripped (alarm) state
Current run command source
communications errors
29
Value (hex.)
00: OFF
01: ON
00: OFF
01: ON
00: Inverter
01: DeviceNet
01: Inverter running
02: Inverter not ready to
run
03: Inverter ready to run
04: Inverter running
05: During deceleration
06: Stop due to
communication broken
07: Tripped
00: Stopped/Running
reverse
01: Running forward
00: Stopped/Running
forward
01: Running reverse
00: State = Value except
below
01: State = 03 to 05
00: Not tripped
01: Tripped
00: No warning
00 → 01: Request for reset
00: Inverter
01: DeviceNet
Refer to Chapter 9.
R/W
Data size
R/W
Byte
R/W
Byte
R/W
Byte
R
Byte
R
Byte
R
Byte
R
Byte
R
Byte
R
Byte
R/W
Byte
R
Byte
R/W
Byte