7.2.2 Extended Speed Control Instance (factory default)

(1) Output (from master to inverter): o31=0 or 21
Instance byte
bit 7
21
0
-
1
(Fixed at 00)
2
Speed Reference (lower byte) (r/min)
3
Speed Reference (upper byte) (r/min)
Run Forward:
Run Reverse:
Fault Reset:
NetCtrl:
NetRef:
Speed Reference:
(2) Input (from inverter to master): o32=0 or 71
Instance byte
bit 7
71
0
At
Reference
1
Drive State
2
Speed Actual (lower byte) (r/min)
3
Speed Actual (upper byte) (r/min)
Faulted:
Running Forward:
Running Reverse:
Ready:
CtrlFromNet:
RefFromNet:
At Reference:
Drive State:
Speed Actual:
bit 6
bit 5
NetRef
NetCtrl
1 = Run forward command
1 = Run reverse command
1 = Reset the alarm condition
1 = Request for enabling run command sent from DeviceNet;
0 = Request for enabling run command sent from other than DeviceNet
1 = Request for enabling speed reference sent from DeviceNet;
0 = Request for enabling speed reference sent from other than DeviceNet
Speed reference (in r/min)
bit 6
bit 5
Ref
Ctrl
FromNet
FromNet
1 = The inverter has (and remains) tripped.
1 = The motor is running forward.
1 = The motor is running backward (in the reverse direction).
1 = Ready to run
1 = Run command sent from DeviceNet being enabled
0 = Run command sent from other than DeviceNet being enabled
1 = Speed reference sent from DeviceNet being enabled
0 = Speed reference sent from other than DeviceNet being enabled
1 = The motor is running at the reference speed.
1 = Startup, 2 = Not Ready, 3 = Ready, 4 = Enabled, 5 = Stopping,
6 = Fault stop, 7 = Faulted
Actual rotation speed (in r/min)
bit 4
bit 3
-
-
Fault
Reset
bit 4
bit 3
Ready
Running
Running
Reverse
Forward
18
bit 2
bit 1
bit 0
Run
Run
Reverse
Forward
bit 2
bit 1
bit 0
-
Faulted