Even modifying S05 or S19 data reflects its change into S01 only. To monitor speed in frequency
or r/min., therefore, select communication-dedicated function code M09 or M78.
For details about configuring the inverter's function codes using o48 to o51, see item (3) below.
Each function code defined has its own data format. For details about the data format of each code,
refer to the RS-485 Communication Use's Manual, Chapter 5, Section 5.2 "Data Formats."
(3) Configuring inverter's function codes o40 to o43 and o48 to o51
Specifying the function code type (shown in Table 7.2) and number in a 4-digit hexadecimal notation.
Function code number (hexadecimal)
Function code type (in accordance with Table 7.2)
Type
Type Code
S
2
02h
M
3
03h
F
4
04h
E
5
05h
C
6
06h
P
7
07h
H
8
08h
A
9
09h
o
10
0Ah
Example: For F26:
Table 7.2 Function Code Type
Function Code
Command/function data
Monitored data
Fundamental function
Terminal function
Control function
Motor 1 parameters
High performance
function
Motor 2 parameters
Optional function
⇒ Type Code 04
F
26 ⇒ 1A (hexadecimal)
Type
Type Code
J
14
0Eh
y
15
0Fh
W
16
10h
X
17
11h
Z
18
12h
b
19
13h
r
12
0Ch
d
20
14h
041a
21
Function Code
Application function 1
Link function
Monitored data 2
Alarm 1
Alarm 2
Motor 3 parameters
Motor 4 parameters
Application function 2