18. AF Laser Axis Check
Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: Background paper (J-250-130-A). Perform this adjustment in the
dark room or use a dark box.
Note2: The data of page: 0, address: 10 must be "00".
Switch setting:
1) POWER ................................................................. MEMORY
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
Checking method:
Order Page Address Data
1
0
01
2
E
EF
3
6
23
4
6
5B
5
6
5C
6
6
90
DB
7
6
91
8
6
92
9
6
93
3A
10
6
01
11
6
01
12
13
Processing after Completing Adjustments:
Order Page Address Data
1
E
EF
2
6
23
3
6
5B
4
6
5C
5
6
90
6
6
91
7
6
92
8
6
93
9
6
01
10
0
01
Paper which reflection rate is 18%
(1m from the front of the lens)
(Note1)
Check operation on LCD screen
Two or more hologram lines are
perfectly within the inspection frame.
The hologram lines can be seen at
every outside of the inspection frame.
Procedure
01
Set the data.
82
Set the data.
04
Set the data.
B4
Set the data.
B4
Set the data.
Set the data.
02
Set the data.
B0
Set the data.
Set the data.
79
Set the data, and press PAUSE
button.
78
Set the data, and press PAUSE
button.
Check that two or more
hologram lines are perfectly
within the inspection frame on
the LCD screen.
Check that the hologram lines
can be seen at every outside of
the inspection frame (the top, the
bottom, the left and the right).
Procedure
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
5-32
Inspection frame
Fig. 5-1-14.