3.3.2

Pre-assignment of the process data output words

The LP_MciOut port block is already implemented in the technology application. The process data
output words are assigned as follows:
Output words
Word 1
Word 2
Word 3
Word 4 ... 16
Status word
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8 ... 11
Bit 12
Bit 13
Bit 14
Bit 15
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
Assignment
Status word (for bit assignment see the following table)
Actual speed value
• Scaling: 16384 ≡ 100 % reference speed (C00011)
Actual torque
• Scaling: 16384 ≡ 100 % maximum torque (C00057)
- (not preconfigured)
Status
1 ≡ Group error active (configurable in C00148)
1 ≡ Inverter control inhibited (pulse inhibit is active)
1 ≡ Drive controller is ready for operation
1 ≡ Quick stop is active
1 ≡ Setpoint torque is in the limitation
1 ≡ actual position is inside the target position window
During open-loop operation:
1 ≡ speed setpoint < comparison value (C00024)
During closed-loop operation:
1 ≡ actual speed value < comparison value (C00024)
1 ≡ Controller inhibited (controller inhibit is active)
Bit coded display of the active device status
Bit 11 Bit 10
Bit 9
Bit 8
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1 ≡ a warning is indicated
1 ≡ a fault is active. The inverter is in the "Trouble" device state.
• The motor has no torque (is coasting) due to the inhibit of the inverter.
• The "Trouble" device status is automatically abandoned if the error cause has been removed.
1 ≡ positioning program running
1 ≡ Home position is known
Device status
Meaning
FirmwareUpdate
Firmware update function is active
Init
Initialisation active
Ident
Identification active
ReadyToSwitchOn
Device is ready to start
SwitchedOn
Device is switched on
OperationEnabled
Operation
-
-
Trouble
Trouble active
Fault
Fault active
TroubleQSP
TroubleQSP is active
SafeTorqueOff
Safe torque off is active
SystemFault
System fault active
19