Troubleshooting

Carbonisation gas duct flap is stiff

5 5 Troubleshooting
5.1 Carbonisation gas duct flap is stiff
Operating Instructions S1 Turbo | B0980113_en
Error characteristics
Carbonisation gas duct flap is
stiff
Little or no draught through
the combustion chamber
when the flap is closed
Clean the carbonisation gas duct flap
❒ Lift off the controller cover and remove the insulating mat beneath it
❒ Unfasten the screws on the inspection cover
❒ Lift off the inspection cover
❒ Clean the carbonisation gas duct flap and flap guides
❒ Clean the entire area using a brush and ash vacuum
Possible cause
Flap guide blocked
Flap cannot be closed due to
dirt and deposits
5
Elimination of error
Check the area under the in‐
spection cover for dirt and de‐
posits and clean if necessary