Permitted Uses; The Clean Air Act 1993 And Smoke Control Areas; Permitted Fuels; Firewood - Froling S1 Turbo Operating Instructions Manual

Firewood boiler
Table of Contents

Advertisement

2

2 2 .4 Permitted uses

2.4.1 The Clean Air Act 1993 and Smoke Control Areas

2.4.2 Permitted fuels

Firewood

Water content
Note on standards
10
The Froling Firewood boiler S1 Turbo is designed solely for heating domestic water.
Only use fuels specified in the "Permitted fuels" section.
⇨ See "Permitted fuels" [page 10]
The unit should only be operated when it is in full working order. It should be operated
in accordance with the instructions, observing safety precautions, and you should en‐
sure you are aware of the potential hazards. The inspection and cleaning intervals in
the operating instructions should be observed. Ensure that any faults which might im‐
pair safety are rectified immediately.
The manufacturer or supplier is not liable for any damage resulting from non-permitted
uses.
Under the Clean Air Act local authorities may declare the whole or part of the district of
the authority to be a smoke control area. It is an offence to emit smoke from a chim‐
ney of a building, from a furnance or from any fixed boiler if located in a designated
smoke control area. It is also an offence to acquire an „unauthorised fuel" for use with‐
in a smoke control area unless it is used in an „exempt"appliance („exempted" from
the controls which generally apply in the smoke control area). The Secretary of State
for Environment, Food and Rural Affairs has powers under the Act to authorise
smokeless fuels or exempt appliances for use in smoke control areas in England. In
Scotland and Wales this power rests with Ministers in the devolved administrations for
those countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, ap‐
plies in Northern Ireland. Therefore it is a requirement that fuels burnt or obtained for
use in smoke control areas have been „authorised" in Regluations and that appliances
used to burn solid fuel in those areas (other than „authorised" fuels) have been ex‐
empted by an Order made and signed by the Secretary of State or Minister in the de‐
volved administrations.
Further information on the requirements of the Clean Air Act can be found here: http://
smokecontrol.defra.gov.uk
Your local authority is responsible for implementing the Clean Air Act 1993 including
designation and supervision of smoke control areas and you can contact them for de‐
tails of Clean Air Act requirements.
Firewood up to max. 55 cm long.
Water content (w) greater than 15% (equivalent to wood moisture u > 17%)
Water content (w) less than 25% (equivalent to wood moisture u < 33%)
EU:
Fuel acc. to EN 14961 - Part 5: Firewood class A2 / D15 L50
Germany
Fuel class 4 (§3 of the First Federal Emissions Protection Ordinance
also:
(BimSchV) in the last amended version)
Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com