How To Use The Warm Up Key - Kinetec Spectra User Manual

Passive mobilisation device of the knee
Hide thumbs Also See for Spectra:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25

How to use the WARM UP key?

Warm Up rules.
The device Kinetec Spectra™ starts at 70% of the full ROM, increasing 5% of the
range each full cycle until the pre-set ROM is reached.
Beginning
To stop the unit
To select Warm Up mode
To start the movement
Note:
- The parameters should only be modified while the unit is stopped.
- Pauses and ByPass mode are not available during warm up cycles.
- The Warm Up cycles are only performed when the movement is first started.
- To start a new Warm Up session, press the "Warm Up" key twice.
- The calculation mode used enables the pre-set ROM to be reached in approximately seven full cycles.
Example:
For a Warm Up treatment with a pre-set ROM from 0° to 100°.
The first cycle starts with 15° to 85° to 15° and the values increase 5% each cycle.
How to define the patient tolerance? • At the start of a session
This function, MODULATION MODE, allows the maximum limits that a patient can tolerate to be
defined and recorded at the beginning of a session.
Set up the patient and proceed as below:
Beginning
Switch the unit ON
To select
MODULATION Mode
To select the pain level
(
for flexion,
for extension)
To set the pain level when reached,
immediately press
To start the session with the new movement
limits
Comments: When the maximum or minimum range of motion of the machine is reached, this
limit is recorded and the MODULATION MODE is automatically switched OFF.
Kinetec Spectra™
Keys to
press
40 STOP
Please Wait
40 STOP
40 RUN
Keys to
press
40 STOP
MODUL.: use +or-
40 STOP
MODUL.: use +or-
Or
40 MANUAL 60
Continuous press
MODUL.: use +or-
40 MANUAL
Or
40 STOP
EN
Display
KINETEC
Check if the hand control is not
45 110
locked (See page 7).
WARM UP
WARM UP
To change the movement value if
45 110
necessary (see page 8).
WARM UP
The angle display changes with the
50
110
current movement.
Display
Check if the hand control is not
locked (See page 7).
KINETEC
50 110
If Warm Up mode is selected, switch
OFF this mode by pressing the "Warm
Up" key.
The display indicates the keys used to
run the machine. This message is
50 110
displayed 3 seconds.
The unit begins to move as selected.
It is waiting for you to select new
110
limits.
The new limit of the movement is
60
60
recorded.
KINETEC
The angle display changes with the
55
60
current movement.
100°
50°
Remarks
Remarks
9/20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents