3 - XY Transport Module Replacement Procedure
3.2
Remove / Re-install the XY Transport Module
Approximate time to remove: 15 minutes plus any sub-procedures
Approximate time to re-install: 15 minutes plus any sub-procedures
The XY transport receives cards from the image printer module and moves them to the embosser module,
then to the exit transport module. It is located along the left side of the device.
Figure 3-1 - Removing and Re-Installing the XY Transport Module (FRONT RIGHT VIEW)
Follow these steps to remove the XY transport module from the device:
1) Disengage and lean back the top access door by following the steps for removing the top access door
in 99875607 ExpressCard 2000 Hardware Service Manual. Stop at the point where the top
access door is leaning up and back behind the device.
2) Move the XY transport toward the front of the device (see 99875607 ExpressCard 2000 Hardware
Service Manual for details).
3) Locate the XY transport's ground cable, which is connected to the deck plate behind the image printer
as shown in Figure 3-2.
ExpressCard 2000| Instant Issuance Card Personalization System | XY Transport Module Replacement Procedure