Parker SS1500 Series Installation & Service Instructions Manual
Parker SS1500 Series Installation & Service Instructions Manual

Parker SS1500 Series Installation & Service Instructions Manual

Pneumatic division.

Advertisement

Quick Links

Click here to view bookmarks.
Pneumatic Division
Richland, Michigan USA
www.parker.com/pneumatics
Bulletin Number
V250D
V251D
V253C
V254BP
V255D
V256CP
Safety Guide
Visit
www.pdnplu.com
additional instruction sheets.
SS VALVE SERIES
SSA/SS150 & SSA/SS1600 Valves, Installation & Service Instructions
SSA/SS1200 & SSA/SS10400 Valves, Installation & Service Instructions
SSA/SS2000 Valves, Installation & Service Instructions
SA Add-A-Fold, Installation & Service Instructions
SSA/SS4000 Valves, Installation & Service Instructions
SSA/SS5000 & SSA/SS6000 Valves, Installation & Service Instructions
PDN Safety Guide
for
Bulletin Description
(02/20/18)

Advertisement

Table of Contents
loading

Summary of Contents for Parker SS1500 Series

  • Page 1 (02/20/18) Click here to view bookmarks. Pneumatic Division Richland, Michigan USA www.parker.com/pneumatics SS VALVE SERIES Bulletin Number Bulletin Description V250D SSA/SS150 & SSA/SS1600 Valves, Installation & Service Instructions V251D SSA/SS1200 & SSA/SS10400 Valves, Installation & Service Instructions V253C SSA/SS2000 Valves, Installation & Service Instructions V254BP SA Add-A-Fold, Installation &...
  • Page 2: Application Limits

    Filtered and lubricated air is necessary for maximum valve life features, specifications, designs, availability and pricing, are subject and minimum maintenance. to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Factory Pre-Lubrication - All valves are pre-lubricated at assembly with a petroleum based grease.
  • Page 3 SSA/SS1500 & SSA/SS1600 Series Valves V-250D Part Identification List Maintenance & Trouble Shooting Hints: Item # Description Air Leakage Through Exhaust Ports: External Pilot Cover 1. Check for internal leakage in cylinder being operated by Screw - body/cover valve. Molded Gasket - valve body to cover 2.
  • Page 4 On dual exhaust models, pipe the supply air into port “P”. On features, specifications, designs, availability and pricing, are subject dual pressure models, pipe the highest supply pressure into to change by Parker Hannifin Corporation and its subsidiaries at any the port that has the highest pressure designation. time without notice.
  • Page 5 SSA/SS1200 & SSA/SS1400 Series Valves V-251D Maintenance & Trouble Shooting Hints: Service Kits and Parts Available SS1200 Series Valve Body Service Kit: Valve Not Shifting When Air Is Energized: (consists of items # 2, 3, 5, 8, 9, 11, & 12) PS5394 1.
  • Page 6 The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject Port Identifications / Connections to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
  • Page 7 SSA/SS2000 Series Valves V-253C Part Identification List Air Leakage Through Exhaust Ports: 1. Check for internal leakage in cylinder being operated by Item # Description valve. Solenoid Assembly 2. Check seals & o-rings for nicks, cracks, and/or cuts. Solenoid Cover with captive mounting screws Solenoid Coil 3.
  • Page 8 The products described herein, including without limitation, product features, (40 in. lb.). specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Note: If more than (6) bases are to be assembled, we...
  • Page 9 SA Series Add-A-Fold V-254BP (2) Nut Couplings (2) Lock Washers Side Plate Side Plate (2) Lock Washers (2) Soc. Hd. Cap Screws SA 1140 Conversion Kit PL3509C Side Plate Kit (2) Side Plates, (3) O-rings, Cap Screws, Couplings and PL5380 Washers To convert SA1110 Internal Exhaust Base to SA1140 External Exhaust Base...
  • Page 10 The products described herein, including without limitation, product assembly with a petroleum based grease. features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any Valves will operate mounted in any position. time without notice.
  • Page 11 SSA/SS4000 Series Valves V-255D Maintenance & Trouble Shooting Hints: Solenoid Service Kit: (consists of items # 5, 6, 7, 8, 9, 10, 12, 13, & 14) PS5397 Valve Not Shifting When Air Is Energized: Note: Two kits are required to service a 1.
  • Page 12: Service Procedure

    - never into the female port. Do not use to change by Parker Hannifin Corporation and its subsidiaries at any PTFE tape to seal pipe joints - pieces have a tendency to break time without notice.
  • Page 13 SSA/SS5000 & SSA/SS6000 Series Valves V-256CP Maintenance & Trouble Shooting Hints Manual Override Kits: Flush Style - Non-Locking PL5178 Valve Not Shifting When Solenoid Assembly Is Flush Style - Locking PL5185 Energized: Parts Identification List 1. Check for proper solenoid operation. 2.
  • Page 14: General Instructions

    1.4. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs or Vacuum products. Do not select, or use Parker valves, FRLs or vacuum products without thoroughly reading and understanding this safety guide as well as the specific Parker publications for the products considered or selected.
  • Page 15 Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling 1-800-CPARKER, or by accessing the Parker web site at www.parker.com.