SECOLink KM24 Short User Manual page 4

Advertisement

Intruder alarm system
Partial disarming
Partial disarming is used when you want to disarm certain areas while leaving other areas armed, or to limit access
to certain areas to other users. Below is an example explaining how to disarm a first partition of two.
, Disarming,
...
4
4
4
4
1 1 1 1
!
!
!
!
GHI
GHI
GHI
GHI
Entry Delay
30
seconds
Press the
key.
Alarm clearing
During an alarm the keypad screen will display a message "Alarm!!!" with an explanation and reasons that caused it.
Red LED light of the
CMS or (and) the user. There are two ways to clear the alarm and turn off the red colored LED light.
,
- this type of clearing will stop the siren sound, turn off the red LED light, and the system will return to the
CLR
CLR
CLR
CLR
prior pre-alarm status. The system will cause an alarm if the system has a smoke detector and an alarm was caused by
smoke from domestic reasons, whether it was armed or disarmed. It is possible to clear this type of alarm by bypassing the
smoke detector (see page 3, "Bypassing zone - B").
- this type of clearing will stop the siren sound, turn off the red LED light, and the system will be disarmed, even if it was
armed previously by entering the PIN code. It is not recommended to use a PIN code for alarm clearing when all partitions
(areas) controlled by the user are disarmed due to a possible casual arming.
Event log review
All events related to protected premises and statuses of the system are stored in the event log. This log will display
all events chronologically and includes information, such as types of alarms, troubles or breakages, control events,
and more. Use
, Event Log
, Alarm Events
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
, Event Log
,
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
Sensor operation testing, testing zones
It is recommended to perform sensor operating testing at least once per month. During testing it will be necessary to
make some type of violation in order to check the functionality of available sensors. For example, opening a door or
windows with magnetic contacts, stimulating movement near the motion sensors, or by hard clapping of hands to
test the glass break detectors.
,
Test
, Burglary zone test
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
10/02
. .
25°C
14:02
READY TO ARM
1st Floor
2nd Floor
Press the
key.
ENT
ENT
ENT
ENT
Violated zones (#) can be checked by pressing
Permission to make system changes (service mode entry)
An installer will have permission to make system changes settings only after a user approves it by entering a
PIN code for security reasons. There are two ways to allow the installer to begin system changes:
,
Service Mode
ENT
ENT
ENT
ENT
,
ENT
ENT
ENT
ENT
Change activated user's PIN code
SECOLINK manufacturer will provide a 4-digit PIN code of the system which is generated in a sequential order,
unique to each user, and is related to his/her number in the system. For example, first user's default PIN code will be
0001, second user's default PIN code will be 0002, and so on. It is strongly recommended to change your default
PIN code in one of these two ways:
, Settings
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
Changed.
,
,
ENT
ENT
ENT
ENT
The factory default PIN should be used temporary and changed as soon as possible to new one. It is recommended to
change old PIN to new one avoiding the PIN that could be used as default for other users (default PIN range 0000 to 0063). It
Page 4
,
,
.
ENT
ENT
ENT
ENT
Partitions
Disarming
1
All partitions
2 2nd Floor
Press [ENT] to disarm
Press [1]..[4] to select part.
Press the
key.
1 1 1 1
key will turn on, the siren will start to sound aloud, and a report about the alarm will be sent to
CLR
CLR
CLR
CLR
and
keys for navigation and viewing next or previous events in the event log.
,
;
ENT
ENT
ENT
ENT
Trouble Events
,
ENT
ENT
ENT
ENT
,
.
ENT
ENT
ENT
ENT
Main Menu
Test
1 Set tings
1
2
Test
2 Fire zone test
3 Event Log
3 Send test report
4 Controls
4 Technical information
5 Service Mode
Press
, then
.
ENT
ENT
ENT
ENT
,
.
ENT
ENT
ENT
ENT
.
,
Users
, Change PIN
ENT
ENT
ENT
ENT
, New PIN:,
enter new PIN, Repeat:,
1st Floor
#
Press the
key.
Enter your PIN code
ENT
.
Zones
Burglary zone test
1
Entry Door
2 Hallway
3 Living room
4 Bedroom
5 Kitchen
6 Bathroom
Press the
key.
ENT
ENT
ENT
ENT
and
keys. To end testing press
,
, New PIN:,
enter new PIN, Repeat:,
ENT
ENT
ENT
ENT
repeat the new PIN, Changed.
KM24, KM24A, KM24G keypad
KM24, KM24A, KM24G keypad
10/02
Disarm
Enter PIN
.
First partition is disarmed,
second partition remains armed.
Zones
1
Entry Door
2 Hallway
3 Living room
4 Bedroom
5 Kitchen
6 Bathroom
Testing zone is not
Testing zone is violated
violated.
.
ENT
ENT
ENT
ENT
Short user manual
. #
25°C
14:02
Armed
2nd Floor
#
(passed test).
repeat the new PIN,

Advertisement

loading
Need help?

Need help?