Intruder alarm system
Bypassing zone
Bypassing a zone allows you to leave a door or window open while arming the rest of your security system. There
are two different types of bypass: temporal or permanent. Temporal bypass is used for a one time arming and
disarming cycle. Permanent bypass is used until the user unbypasses the zone. Enter the zone number you would like to
bypass. THIS MUST BE A TWO DIGIT NUMBER. The zone will be marked as " ". To bypass the zone for a long time
(permanent) the last number should be pressed and held for 2 sec. A zone will be marked as " ". Press
marked. The same actions can be performed by choosing the zone with
key (short press - temporal, long - permanent). To bypass follow the steps below:
# # # #
, Zone bypass,
,
B
B
B
B
!
!
!
!
BY
BY
BY
BY
10/02
. .
25°C
14:02
READY TO ARM
1st Floor
2nd Floor
Press the
key.
B
B
B
B
!
!
!
!
BY
BY
BY
BY
10/02
. .
25°C
14:02
READY TO ARM
1st Floor
2nd Floor
Press the
key.
B
B
B
B
!
!
!
!
BY
BY
BY
BY
Abort arming
Clear
key is used for selecting and aborting procedures. For example, if exit delay is in process and you want to
CLR
CLR
CLR
CLR
abort arming, press the
Arming system with troubles
EU standards do not allow the use of a troubled security system. Green LED light of the
arming of the system with previously described ways will not be possible. It is necessary to immediately eliminate
system troubles, inform CMS, and the company that had installed your system. The system detects troubles of its
own modules as well as other common problems such as 230V disappearance in AC line, a disconnected phone line due to
repairs, or a battery discharge. In exceptional cases it is possible to bypass certain troubles for a short period of time and arm
the system as usual. To arm a system with troubles please do the following:
Press the
key once and a message describing system troubles will be shown on the display. Press
CLR
CLR
CLR
CLR
LED light will start to blink rapidly. Blinking duration is 30 seconds and during this time it is possible to activate Arming of your
system as usual.
Emergency keys
To activate an emergency function press at once two event specific keys listed below and hold it for at least 1
second. Premises must be secured by CMS for these functions to activate. An audible emergency loud siren will
occur showing a related message on the keypad screen.
Fire alarm:
Medical alarm:
Panic alarm:
Ways of disarming
Disarming can be done in two ways: with a special
selected partitions when disarming is activated with the
which will be disarmed (unmark the partitions by pressing
unmark/mark by pressing
activated by entering a PIN code.
To Disarm the System Using Your PIN Code Upon Entering the Premise
Entry delay gives you time to disarm the system when you enter through the designated entrance door. You must
disarm the system before entry delay period ends to avoid an alarm occurrence. There are two ways to disarm the
system using your PIN code:
, Disarming,
PIN code:
...
or
,
and
,
9
9
9
9
0 0 0 0
# # # #
ENT
ENT
ENT
ENT
WXYZ
WXYZ
WXYZ
WXYZ
Zones
Zone
1
Bypass
2 Hallway
3 Living room
4 Bedroom
5 Kitchen
Enter PIN
6 Bathroom
Enter your PIN code
.
Zone named Entry Door is
Zones
Zone
1
Bypass
2 Hallway
3 Living room
4 Bedroom
5 Kitchen
Enter PIN
6 Bathroom
Enter your PIN code
.
Zone named Entry Door is
violated (!). Press the
and hold it for 2 seconds.
key and enter your PIN code.
CLR
+
.
A A A A
1 1 1 1
+
.
4
4
4
4
B
B
B
B
!
!
!
!
!
!
!
!
BY
BY
BY
BY
GHI
GHI
GHI
GHI
+
.
7
7
7
7
C C C C
PQRS
PQRS
PQRS
PQRS
, or
keys). All partitions which are controlled by the user will be disarmed when disarming is
# # # #
,
.
ENT
ENT
ENT
ENT
.
or
Zones
Entry Door
!
1
Entry Door
2 Hallway
3 Living room
4 Bedroom
5 Kitchen
6 Bathroom
violated (!). To bypass
press the
key.
# # # #
Zones
Entry Door
!
1
Entry Door
2 Hallway
3 Living room
4 Bedroom
5 Kitchen
6 Bathroom
key
# # # #
key or by entering a PIN code. User has an option to disarm all or
key. For partial disarming it's necessary to unmark the partitions
...
keys or select partitions by pressing
4
4
4
4
1 1 1 1
!
!
!
!
GHI
GHI
GHI
GHI
KM24, KM24A, KM24G keypad
KM24, KM24A, KM24G keypad
keys and by marking a chosen zone with the
10/02
x
BYPASSED
Zone is bypassed
temporarily.
Press the
key.
ENT
ENT
ENT
ENT
10/02
X
BYPASSED
Zone is bypassed
permanently.
Press the
key.
ENT
ENT
ENT
ENT
CLR
CLR
CLR
CLR
CLR
CLR
CLR
CLR
Short user manual
when all zones are
ENT
ENT
ENT
ENT
. .
25°C
14:02
Entry Door
. .
25°C
14:02
Entry Door
key will turn on and
again and the Green
,
keys and
Page 3

Advertisement

loading
Need help?

Need help?

Do you have a question about the KM24 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Related Products for SECOLink KM24

This manual is also suitable for:

Km24aKm24g