Lenovo System x3650 M5 Installation And Service Manual page 1108

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

Serviceable
No
Automatically notify support
No
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 089-801-000 : CPU Stress Test Aborted
CPU Stress Test Aborted. Internal Program Error.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. Check system firmware level and upgrade if necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest
level firmware for this component can be found in reference to this system type at the IBM
Support website.
5. Run the test again.
6. If the system has stopped responding, turn off and restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 089-802-000 : CPU Stress Test Aborted
CPU Stress Test Aborted. System resource unavailability error.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
1096