Non-Hot-Plug Components; Opening The Server; Opening The Server - Floorstand Model - Fujitsu PRIMERGY TX150 S6 Operating Manual

Hide thumbs Also See for PRIMERGY TX150 S6:
Table of Contents

Advertisement

CSS components
8.2

Non-hot-plug components

If a CSS error is displayed but none of the hot-plug components is displaying an
error, proceed as follows:
Ê Exit all applications and shut down the server properly.
Ê Press the On/Off button if the server has not been switched off by the
operating system.
Ê Pull all power connectors out of the power outlets.
8.2.1

Opening the server

8.2.1.1

Opening the server - floorstand model

Ê If required, remove the lock on the side cover.
Figure 39: Removing the left-hand side cover
Ê Unlock the server (1).
Ê Loosen the two knurled screws at the rear side (2).
Ê Push back the left-hand side cover approxiate 2 cm (3).
Ê Remove the left-hand side cover (4).
TX150 S6
4
2
Operating Manual
Non-hot-plug components
3
1
105