Download Print this page

Installation - Graco J Series Instructions-Parts List Manual

55 gallon 200 liter drum size air-powered ram

Advertisement

Mounting the Pump (Model 207–279 Ram)
NOTE: The Pump Selection Chart on page 3 lists pumps
commonly mounted on this ram. Installing other
pumps on the ram may require alternate parts,
which are packed in separate plastic bags. For
information, contact your Graco representative
or
Graco
Technical
1–800–543–0339.
Mount the pump as follows. Refer to the Typical Installa-
tion on page 4.
1. Remove the mounting plate (58); it is not required for
those pumps listed in the chart on page 3. Position
the mounting brackets (57) so that the top of the
pump will clear the support beam (3). Set the pump
on the mounting brackets (57) with the air inlet
toward the ram director valve (4). Attach the pump to
the mounting brackets with the screws (27) and
washers (26) provided.
2. Remove the four screws (25) and washers (31)
holding the standard seal plates (62) to the ram plate
(63) and remove the top seal plate (62) and seal (56).
Leave the bottom seal plate (62) and gasket (61) in
place. See Fig 1.
STANDARD EXTRUSION
PUMPS
PUMP INTAKE
HOUSING
62
62
Fig 1

INSTALLATION

3. For 15:1 and 25:1 ratio Senator, 25:1 and 40:1 ratio
Assistance
at
4. Loosen the mounting bracket setscrews (35), and
5. If applicable for your installation, push the seal (56)
6. Align the holes in the top seal plate or pump intake
56
25, 31
61
63
Bulldog, and 55:1 ratio King standard extrusion
pumps, slide the top seal plate (62) up over the pump
intake valve and push the seal (56) onto the pump
intake housing. Then continue with step 4.
For 10:1 ratio Bulldog and 20:1 ratio King pumps with
a flanged intake housing, discard the top seal plate
(62) and seal (56). Remove and discard the bottom
seal plate (62). Align the holes in the intake valve
flange with those in the gasket (61) and ram plate
(63). Then continue with step 4.
carefully lower the pump until the intake valve is be-
low the gasket (61), then tighten the setscrews.
down firmly against the bottom seal plate (62).
flange (as applicable) with the holes in the ram plate
(63). Secure tightly to the ram plate with the four
screws (25) and washers (31).
10:1 BULLDOG AND 20:1 KING PUMPS,
WITH FLANGED INTAKE HOUSING
INTAKE
HOUSING
FLANGE
25, 31
61
63

Hide quick links:

Advertisement

loading

This manual is also suitable for:

A series207-279223-634