Dcs thyristor power converters for dc drive systems 25 to 5150 a/10300 a. manual for 12 – pulse operation parallel/serial/sequential
Hide thumbs Also See for DCS 600 MultiDrive Series:
Table of Contents

Advertisement

Chapter 4 – Twelve–Pulse Serial / Sequential Configurations with DCS 600
Measuring the DC voltage
(serial / sequential mode)
[continued]
Solution 1:
SDCS-PIN-51
high-resistance
measurement
4 - 8
II F2
For Solution 1 the hardware coding of the voltage measurement
channels of the standard converters must be rescaled.
Note: This SDCS-PIN-51 modification (Solution 1) is possible up
to a rated supply voltage 500 V AC!
Complete 12 – pulse serial and sequential configurations
including units of the series DCA 600 enclosed con-
verters – as delivered from ABB – already feature the
required rescaling measures as an option.
Rated line (supply)
voltage [V]
200 ... 250 **)
250 ... 300
300 ... 350
350 ... 400
400 ... 500
*)
See Manual „Technical Data" (resistors W1 ... W 26)
**) No changes of voltage coding are required for 400 V and 500 V
standard converters of size C4!
SDCS-PIN-51
voltage coding *)
500
600
690
790
1000
DCS 600 Manual for 12 – Pulse Operation
Software coding
S CON NOM VOLT
(42.08)
500
600
690
800
1000