Loosen the automated air vent one turn (fig. 29).
Connect the system to the mains power supply.
Set the switch on the BC10 to "1" (see fig. 28, item 3)
Press the service button (fig. 28, item 4) until the system
pressure (for example P1.1) appears in the display.
If necessary open the CH flow and CH return maintenance
valves (fig. 30, item 1 and 2).
Connect temporary hose (fig. 31).
Open both stop valves.