Star Micronics LC-8021 User Manual page 37

Star printer user's manual lc-8021
Table of Contents

Advertisement

EDS-2 Settings
The following details all of the settings you can make for EDS-2. For
communications protocol settings (Banks A and B), the matching settings you
have to make in your MS-DOS AUTOEXEC.BAT file.
BANK A
Switch 1: Data Length
Specifies the number of bits that the computer transmits as one byte. This setting
is normally 8.
Data Length
8 bits
7 bits
Switch 2: Parity Check
This switch specifies whether or not a parity check should be performed on the
data.
Parity Check
Disabled
Enabled
Switch 3: Parity
This switch specifies the parity as non, odd, or even.
Parity
Even
Odd
SW1
DOS Setting
ON
OFF
SW2
DOS Setting
ON
OFF
SW3
DOS Setting
ON
OFF
EDS-2 Settings
8
7
Disabled
Enabled
O
E
31