Preface General Product Manual The Trifecta XPro Series is the preferred solution for reliable The Trifecta XPro Series Product Manual is designed to be and continuous laser assist gases for delivery pressures up used in conjunction with all Trifecta models provided by to 550 psig and flow rates up to 15,000 scfh.
Preface Product Manual - Trifecta XPro Series ® Terms Acronyms / Abbreviations Throughout this manual safety precautions will be designated The following acronyms / abbreviations are used throughout as follows: this manual: Pressure (Metric) Warning! Description of a condition that can result in personal injury or Compressed Gas Association death.
General Flow Capacity Congratulations, you are now the owner of a Chart Trifecta The Trifecta XPro Series system is designed to supply high XPro Series high-pressure gas supply system pressure cryogenic liquid to a vaporizer, while the reserve tank is being filled with lower pressure liquid. Its priority is...
Page 8
Introduction Product Manual - Trifecta XPro Series ® – Special care must be given in selection of the bulk The flow performance depends on the ability of the total system to: tank that supplies the Trifecta – The tanks heat leak performance is critical in •...
Product Manual - Trifecta XPro Series ® Safety General Excess accumulation of oxygen creates an oxygen-enriched atmosphere (defined by the Compressed Gas Association as an oxygen concentration above 23%) Certain items All operators should have a full and complete understanding of the content of this manual before operating the equipment considered non-combustible in air may burn rapidly in described This manual is intended to describe the operation...
Transporting and erection of the tank should be performed in accordance with rigging instructions available from Chart Failure to comply with these instructions may result in Oxygen Deficient Atmospheres serious damage to the container...
Product Manual - Trifecta XPro Series Safety ® Human exposure to an atmosphere containing 12% or less Compatibility involves both combustibility and ease of oxygen leads to rapid unconsciousness Unconsciousness can ignition Materials that burn in air may burn violently in pure occur so rapidly that the user is rendered essentially helpless oxygen at normal pressure, and explosively in pressurized This can occur if the condition is reached by an immediate...
Page 12
ASME standards to include a dual relief valve While water (105-115ºF or 41-46ºC) DO NOT USE HOT WATER Chart equipment is designed and built to the most rigid Cryogenic burns that result in blistering or deeper tissue standards, no piece of mechanical equipment can ever be...
Venting the Trifecta to the gas phase is often useful when connecting multiple Trifectas to one bulk The Trifecta XPro Series skid has four lifting lugs on the top tank of the skid These lifting lugs allow for placement of the skid The backside (PB Side) of the XPro Series skid has two/three by overhead crane.
XPro Series “Gas Use” relief device may vent liquid, creating a noticeable vapor cloud. The piping and components from the Trifecta XPro Series to the vaporizer must be at least 3/4” (19mm) copper or its equivalent and of adequate pressure rating Small diameter lines will introduce undesirable pressure drops and impact...
Trifecta XPro Series and pre-wired into the control box before running the system with No additional piping is required by the customer to receive liquid.
Page 16
Installation Product Manual - Trifecta XPro Series ® • Purge for one minute Purge and Pre-Charge of the Trifecta XPro Series Cont. • Close the manual vents (V-1) • Crack both of the 1/4” Swagelok nuts on the bottom of ®...
Page 17
Installation ® • Open the P B Isolation valve on the bottom of tank 1 and Purge and Pre-Charge of the Trifecta XPro Series tank 2 (V-3) Cont. • Open the P B Isolation valve on the bottom of tank 1 and tank 2 (V-3) •...
XPro Series ® • Turn the switch on the front of the control box to run Purge and Pre-Charge of the Trifecta XPro Series Cont. • Once both tanks are filled and pressured up, allow all • Leak check all pressurized lines lines to thaw •...
Product Manual - Trifecta XPro Series ® Operation Parameter Settings Setting Pressure Set Points Initial power up from the factory will require some Three settable parameters are accessible from the PLC parameters to be set. The display flashes “Reset Values” on buttons These parameters are key to setting all parameters the lower line of the main display No valves will operate while this display is flashing.
Operation Product Manual - Trifecta XPro Series ® Setting Fill Set Point Setting Bulk Tank Critical Pressure Note: Since the tanks are warm upon initial installation, they may vent for several minutes before they are cold enough to accumulate liquid. • Pressing the “Up” arrow button accesses the fill set point. The “Fill”...
Hard Sets The Trifecta XPro Series operation is based on pressure first, and liquid level second. This logic assures that the system pressure is maintained as pressure is the primary concern The following table is intended to give detailed information of the...
Page 22
Operation Product Manual - Trifecta X-Series ® Hard Sets cont. HardSets Thresholds Factory Default Adjustable Description 29.0" Yes (up arrow) default fill level 7.3" Yes (function of fill level) primary to low to assist (.25 x fill level) 24.7" Yes (function of fill level) secondary to low for assist mode (.85 x fill level) Yes (function of PB On) PBOff = PBOn + 25psi 550 psi default PBOn 425 psi...
X-Series Operation ® Operation Details The Trifecta XPro Series logic keys on pressure instead of liquid level The components have been minimized (reduced) yet the design has duplication of key components See Table 1 LIQUID FROM BULK VENT TO BULK...
Service Service Menus Error Codes The Trifecta XPro Series PLC has built into the program The PLC reviews timers, flows, values and counters to assure service information and error codes they are within reason If the PLC determines that they are not within reason an error code will be displayed If the PLC determines that there is a service issue “Check...
Check for house line leaks. exceeded the flow Check for system leaks. rating. Need additional or next size Trifecta XPro Series. Manually Operating the Valves None With the system in the “Monitor” mode, valves and valve One of the systems Check electrical connects.
Service Product Manual - Trifecta XPro Series ® Fuses Fuse # Voltage Fuse Type (Amps) Device(s) Protected Chart Part Number FU101 110AC MDA-10 (10) Main (Panel) 11832443 FU203 110AC MDL-2 (2) PB Valve/Light Side 1 11832398 FU205 110AC MDL-2 (2)
Ball Valve Repair (Trifecta XPro Series - 600 psig only) Moisture in Solenoid Early versions of the 600 psig Trifecta XPro Series used Solenoid should be allowed to thaw. Once thawed, moisture cryogenically rated ball valves in place of solenoid valves...
Procedure • Every year: – Verify two normal operation cycles Over time components of the Trifecta XPro Series (as in any mechanical system) can degrade and/or fail if not properly – Inspect integrity of all wire connections in control maintained. For this reason, a regular maintenance procedure...
Preventive Maintenance Product Manual - Trifecta XPro Series ® Recommended Spare Parts In the event that repair is necessary, Chart provides the following spare parts at www chartparts com Control Box Item Description 1 Item Description 2 Chart PN FUSE FU101 MDA-10 (10 AMP MAIN PANEL)
Leak check all plumbing components transmitters Check for discrepancies between analog gauges and • A leak at any point in the Trifecta XPro Series system controller parameters will result in loss of product The above steps are described in greater detail below and •...