Specifications; Double Insulation - IDEAL 61-614 Instruction Manual

Analog multimeter
Table of Contents

Advertisement

Available languages

Available languages

ND 1723-2 61-614 Instructions

Specifications:

Sensitivity:
8kΩ/VAC, 20kΩ/VDC
Fuse:
(1) 0.5A, 250V, 0.25" x 1.25", miniature glass fuse (IDEAL #F-1)
Battery:
(2) 1.5V AA type battery.
Operating:
32°F to 122°F (0°C to 50°C)
Environment Maximum Relative Humidity <80% @ 31°C /
Minimum 50% @ 40°C)
Dimensions: 5.4"H x3.7"W x1.8"D (137mm H x95mm W x45mm D)
Weight:
9.5 oz (270g)
Safety:
UL, cUL, CE
Accessories included: Test Leads (#TL-56), (2) 1.5V AA type batteries, operating
instructions.
Ranges & Accuracies:
AC Voltage:
0-10/50/250/1000 ACV
DC Voltage:
0-2.5/10/50/250/1000 DCV +/-3% FS
DC Current:
0-5m/50m/500m/20 ADC
Resistance:
0-50/500/50k Ω Mid-scale +/-3% of Arc Length
0-10k/100k/10M Ω Full-scale +/-3% of Arc Length
Decibels:
-8 to +62 dB on ACV ranges
Battery Check: 1.5V / 9V ranges
Continuity Beeper

Double Insulation

Instrument has been evaluated and complies with insulation category II (overvolt-
age category II). Pollution degree 2 in accordance with IEC-644. Indoor use.
1/9/07
9:48 AM
Page 9
+/-4% FS
+/-3% FS