Technical specifications -
Type
Output
steps
[kW]
RDS23E08
2,7/5,4/8,1
RDS29E12
3,9/7,8/11,7 1300/2900
RDS38E18
6,0/12,0/18,0 1800/3800
RDS56E23
7,8/15,6/23,4 2700/5600
9,9/18,8/29,7 3100/6500
RDS65E30
Technical specifications -
Typ
Output*
Output*
4
[kW]
[kW]
RDS23WL
10,3
17,9
11,7
20,4
RDS29WL
RDS38WL
17,3
29,8
RDS56WL
25,5
43,3
RDS65WL
32,0
54,1
*
) Lowest/highest airflow of totally 5 fan steps.
1
*
) Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m².
2
) ∆t = temperature rise of passing air at maximum heat output and lowest/highest airflow.
*
3
*
) Applicable at water temperature 60/40 °C, air temperature, in +18 °C.
4
*
) Applicable at water temperature 80/60 °C, air temperature, in +18 °C.
5
*
) Approximate weight for air curtain and duct.
6
The data are estimated average values which are affected by the shape of the exhaust duct.
Protection class: IP20.
CE compliant.
14
3
Electrical heat - RDS E
∆t
Airflow*
Sound
1
*3
level*
[m
/h]
[°C]
[dB(A)]
3
1050/2300
23/11
60
27/12
61
30/14
62
26/12
63
29/14
64
Water heat - RDS WL, coil for low water temperature (480 °C)
∆t
Airflow*
5
1
*3,4
[m
3
/h]
[°C]
1050/2300 18/13 31/23 2,2
1300/2900 17/12 29/21 2,2
1800/3800 18/13 31/23 3,4
2700/5600 18/13 30/23 4,5
3100/6500 19/15 32/25 5,7
RDS
Voltage [V]
Voltage [V]
Amperage [A]
Amperage [A]
2
(control)
(heat)
230V~/2,3
400V3~/11,7
230V~/3,6
400V3~/16,9
230V~/4,8
400V3~/26,0
230V~/7,0
400V3~/33,8
230V~/8,2
400V3~/42,9
2
∆t
Water
Sound
*3,5
volume
level*
1
[°C]
[l]
[dB(A)]
60
61
62
63
64
Length
Weight*
[mm]
[kg]
1000
80
1000
100
1500
150
2000
200
2500
220
Voltage
Amperage
Length
[V]
[A]
[mm]
230V~
2,3
1000
230V~
3,6
1000
230V~
4,8
1500
230V~
7,0
2000
230V~
8,2
2500
6
Weight
*6
[kg]
80
100
150
200
220

Advertisement

loading