Summary of Contents for Frico RDS

  • Page 1 Original instructions ..14 ..19 ..25 ..21 ..30 ..35 ..40 ..45 ..50 ..55...
  • Page 2: Top View

    Top view [mm] RDS23 1000 RDS29 1000 RDS38 1500 RDS56 2000 RDS65 2500 Side view...
  • Page 3 Suspended from ceiling 8 x M8 RDS23 RDS29 RDS38 RDS56 RDS65 10 x M8...
  • Page 4 Mounted on revolving door Connections position W Connections position E 400V 230V~ RDSB 40x80...
  • Page 5 Accessories SIRe SIReB SIReAC SIReAA SIReB SIReUR 70x33x23 mm SIReRTX SIReUR 114x70x50 mm SIReWTA SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 10 m SIReCC610 SIReAC/SIReAA SIReCJ4/SIReCJ6 15 m SIReCC615 40 m SIReCC640 SIReCC403 SIReCC405 10 m SIReCC410 15 m SIReCC415 SIReRTX SIReCC Type Connection VMOP...
  • Page 6 RDS + RDSB (beam)
  • Page 7 RDS E Transformer Transformer SIReB1 Actuator Supply 230V~ 230V~ ROOM...
  • Page 8 RDS W Transformer Transformer SIReB1 Actuator Supply 230V~ 230V~ ROOM...
  • Page 9 SIReB Basic RDS A RDS E SIReUB1 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) SIReCC6XX (max 10 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot.
  • Page 10 SIReB Basic RDS W SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 10 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SD230...
  • Page 11 Output charts water Supply water temperature: 80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water flow drop air temp. flow drop temp.
  • Page 12 42,0 0,56 50,8 26,4 30,0 0,32 17,6 3100 14,4 30,0 0,14 16,7 33,9 0,20 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 13: Technical Specifications

    RDS56E23 7,8/15,6/23,4 2700/5600 26/12 230V~/7,0 400V3~/33,8 2000 RDS65E30 9,9/18,8/29,7 3100/6500 29/14 230V~/8,2 400V3~/42,9 2500 Water heat - RDS WL, coil for low water temperature (480 °C) ∆t ∆t Type Output* Output* Airflow* Water Sound Voltage Amperage Length Weight *3,4 *3,5...
  • Page 14: Operation

    Read these instructions carefully before the roof of the revolving door cannot take installation and use. Keep this manual for the weight, RDS can be mounted on a beam future reference. construction. Mounting brackets for beam The product may only be used as set out in included.
  • Page 15: Maintenance

    Note that the unit shall be preceded by a cleaning is necessary. The level of cleaning regulating valve, see Frico valve kit. can vary depending on local conditions. The water coil is connected on the side of the unit via DN25 (1’’), internal thread...
  • Page 16 Fan replacement Residual current circuit breaker (E) Fans are replaced through the bottom service When the installation is protected by means hatch. Alternatively the screws of the bottom of a residual current circuit breaker, which service hatch are slackened and the fans are trips when the appliance is connected, replaced through the top service hatch.