Download Print this page

Frico AGS5500 Original Instructions Manual

Hide thumbs Also See for AGS5500:

Advertisement

Available languages

Available languages

Quick Links

SE
.... 15
IT
.... 34
GB
.... 19
NL
.... 38
DE
.... 22
NO
.... 42
Original instructions
AGS5500
ES
FR
.... 26
PL
.... 46
RU
.... 30
.... 50

Advertisement

loading

Summary of Contents for Frico AGS5500

  • Page 1 Original instructions AGS5500 ..22 ..30 ..26 ..15 ..19 ..38 ..46 ..34 ..42 ..50...
  • Page 2 AGS5500 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
  • Page 3 AGS5500 PC board (2 x for AGS5525/5530) SIRe AGS5515: 4 x M10 AGS5520/5525: 6 x M10 AGS5530: 8 x M10 AGS5520/5525 Inside thread [mm] AGS5515 1515 AGS5515 DN25 (1") DN20 (3/4") AGS5520 2010 AGS5520 DN32 (1 1/4") DN25 (1") AGS5525...
  • Page 4 AGS5500 min 200 Fig. 2. Minimum distance Fig. 3. Installation alternatives Fig. 4. Open the unit...
  • Page 5 AGS5500 AGS5500 + GWB640 Type Wall bracket GWB640 AGS5515 2 pcs AGS5520 3 pcs AGS5525 3 pcs 4 pcs AGS5530 GWB640 20 mm 20 mm 20 mm Fig. 5. Mounting bracket GWB640...
  • Page 6 AGS5500 SIRe SIReBN SIReAC SIReAA SIReB SIReUR SIReRTX 70x33x23 mm SIReUR 114x70x50 mm SIReWTA SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReAC/SIReAA SIReCJ4/SIReCJ6 SIReCC610 10 m SIReCC615 15 m SIReCC640 40 m SIReCC403 SIReCC405 SIReRTX SIReCC SIReCC410 10 m SIReCC415 VMO20 DN20...
  • Page 7 AGS5500 Output charts water AGS5500WH Supply water temperature: 110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water temp.
  • Page 8 AGS5500 Output charts water AGS5500 WL Supply water temperature: 80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water temp.
  • Page 9: Technical Specifications

    2010 5000/11000 27/20 52/72 230V~ 15,4 2520 AGS5525WH AGS5530WH 6250/13750 27/20 54/74 230V~ 19,3 3030 AGS5500 WL with water heat, coil for low temperature water < 80/60 °C ∆t Type Output* Airflow Water Sound Voltage Amperage Length Weight *3,5 volume...
  • Page 10 AGS5500 AGS5515 / AGS5520 Transformer Transformer Actuator 230V Supply 230V Room 230V~...
  • Page 11 AGS5500 AGS5525 / AGS5530 Transformer Actuator 230VSupply 230V Room Transformer Transformer Actuator 230VSupply 230V Room 230V~...
  • Page 12 AGS5500 SIReB Basic AGS5500A SIReUB1 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) SIReCC6XX (max 10 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot.
  • Page 13 AGS5500 SIReB Basic AGS5500 W SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 10 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m)
  • Page 14: Montaje

    3 mm como Aplicación La cortina de aire AGS5500 está disponible mínimo, debe encargarse a un electricista cualificado y efectuarse con arreglo a la en versión sin calor o calor por agua. La última edición de las normas IEE sobre...
  • Page 15: Mantenimiento

    AGS5500 Mantenimiento válvulas de cierre para permitir una Los motores de los ventiladores y demás extracción sin problemas. La batería de agua componentes no requieren mantenimiento; incorpora válvula de drenaje. Además es basta con limpiarlos siempre que sea preciso instalar una válvula de purga en un necesario.
  • Page 16 AGS5500 Drenaje de la batería de agua (W) Seguridad Las válvulas de vaciado están situadas en • Asegúrese de que no haya nada cerca la parte inferior de la batería, en el lado del de las rejillas de aspiración y descarga conector, y se puede acceder a ellas por el que impida la circulación del aire por la...
  • Page 17 AGSxxx ) Temperatura recomendada del aire de salida para un buen confort y un rendimiento optimizado. ) Rendimiento nominal a una temperatura del agua de suministro y retorno específica. Visite www.frico.com.es para obtener cálculos adicionales. Especificaciones técnicas = Potencia Output*...
  • Page 18 AGS5500...
  • Page 19 AGS5500...
  • Page 20 Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...