Page 2
Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene Les pages de présentation contiennent principalement des images.
Page 11
SIReB Basic RDS A RDS E SIReUB1 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot.
Page 12
SIReB Basic RDS W SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SD230...
Page 13
Output charts water Supply water temperature: 80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water flow drop air temp. flow drop temp.
Page 14
RDS65WL max 5300 24,7 0,33 19,0 23,4 0,28 14,1 2250 10,6 0,10 13,5 35,6 0,16 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
Installation and operating instructions General Instructions the roof of the revolving door cannot take Read these instructions carefully before the weight, RDS can be mounted on a beam installation and use. Keep this manual for construction. Mounting brackets for beam future reference.
Note that the unit shall be preceded by a cleaning is necessary. The level of cleaning regulating valve, see Frico valve kit. can vary depending on local conditions. The water coil is connected on the side of the unit via DN25 (1’’), internal thread...
Page 18
Fan replacement Residual current circuit breaker (E) Fans are replaced through the bottom service When the installation is protected by means hatch. Alternatively the screws of the bottom of a residual current circuit breaker, which service hatch are slackened and the fans are trips when the appliance is connected, replaced through the top service hatch.
Page 19
Safety • For all installations of electrically heated products should a residual current circuit breaker 300 mA for fire protection be used. • Keep the areas around the air intake and exhaust grilles free from possible obstructions! • The unit must not be fully or partially covered as overheating can result in a fire risk! •...
Page 20
Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.net.